推荐产品
等級
certified reference material
形狀
liquid
特點
Snap-N-Spike®/Snap-N-Shoot®
包裝
ampule of 1 mL
製造商/商標名
Cerilliant®
drug control
Narcotic Licence Schedule D (Switzerland)
濃度
100 μg/mL in methanol
技術
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
應用
forensics and toxicology
forensics and toxicology
格式
single component solution
儲存溫度
−20°C
InChI
1S/C23H21NO2/c1-16(25)13-14-24-15-21(19-10-4-5-12-22(19)24)23(26)20-11-6-8-17-7-2-3-9-18(17)20/h2-12,15-16,25H,13-14H2,1H3/i4D,5D,10D,12D,15D
InChI 密鑰
YPRJGJFJMZOUSH-VEJGPVSBSA-N
一般說明
應用
- Synthetic cannabinoid standard: Research on JWH-073 focuses on its effects on cardiac tissue and vascular reactivity, contributing to our understanding of the physiological implications of synthetic cannabinoid consumption (Breivogel et al., 2023).
- Indole-D₅ research chemical: Studies involving JWH-073 have explored its impact on behavior and electrophysiological responses in mice, highlighting its importance in neurological and behavioral research (Barbieri et al., 2022).
- Cannabinoid biochemistry reagent: JWH-073 has been analyzed using micellar electrokinetic chromatography, demonstrating its application in the separation and analysis of synthetic and phytocannabinoids, which is crucial for forensic and clinical toxicology (Laanet et al., 2022).
- 3-Hydroxybutyl JWH-073 derivative: Development of assays for synthetic cannabinoids in saliva using paper-based lateral flow assays indicates the utility of JWH-073 derivatives in developing accessible diagnostic tools (Moulahoum et al., 2021).
- Deuterium-enriched JWH-073 metabolite for mass spectrometry: Research has employed dispersive liquid-liquid microextraction techniques for the detection of JWH-073 in oral fluid, proving its utility in enhancing detection sensitivity and specificity in mass spectrometry analyses (Tomai et al., 2021).
法律資訊
相關產品
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
標靶器官
Eyes
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 1
閃點(°F)
49.5 °F - closed cup
閃點(°C)
9.7 °C - closed cup
商品
LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.
LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门