2-D Clean-Up Kit

Cytiva 80-6484-51

Sinonimo/i:

2D Clean-Up Kit

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41105323
NACRES:
NA.25

Caratteristiche

wetted part: no

Produttore/marchio commerciale

Cytiva 80-6484-51

Confezionamento

pkg of 50 samples

Descrizione generale

2-D Clean-Up Kit is designed to prepare samples for 2-D electrophoresis that otherwise produce poor 2-D spot-maps due to high conductivity, high levels of interfering substances, or low protein concentration. The reagents quantitatively precipitate proteins while leaving interfering substances, such as detergents, salts, lipids, phenolics, and nucleic acids, in solution.

Treatment of the sample with 2-D Clean-Up Kit can improve the quality of 2-D electrophoresis results, reducing streaking, background staining, and other artifacts due to interfering contaminants. The kit can make 2-D analysis possible for samples that are otherwise too dirty or too dilute.

The 2-D Clean-Up Kit procedure uses precipitant and co-precipitant in combination to quantitatively precipitate proteins. Precipitated proteins are pelleted by centrifugation and the precipitate is further washed to remove nonprotein contaminants. After a second centrifugation, the resultant pellet is resuspended into denaturing sample solution for first-dimension IEF.

The procedure can be completed in 90 min and does not result in spot gain or loss. The kit contains sufficient reagents to process 50 samples of up to 100 μ each. The procedure can be scaled up for larger volumes or more dilute samples.

2-D Clean-Up Kit increases labeling efficiency and protein abundance when using 2-D Fluorescence Difference Gel Electrophoresis (2-D DIGE).

Applicazioni

Automated identification and quantitation of proteins and peptides using LC-MS/MS.

Caratteristiche e vantaggi

  • Improves the quality of 2-D electrophoresis results by removing interfering contaminants
  • Quantitative precipitation separates proteins from detergents, salts, lipids, phenolics and nucleic acids
  • Delivers quantitative yield in about 90 min.

Stoccaggio e stabilità

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
The wash buffer should be placed at -20 °C at least 1 h before use and may be s-red in a -20 °C freezer

Risultati analitici

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Pittogrammi

Environment

Avvertenze

Danger

Indicazioni di pericolo

Codice della classe di stoccaggio

8B - Non-combustible corrosive hazardous materials


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Protocolli

Mini Dialysis Kit from GE Healthcare Lifescience is designed for the dialysis of small sample volumes with minimal handling and sample loss and reduces the pronounced streaking on 2-D gels caused by low-molecular-weight contaminants.

Sample Grinding Kit from GE Healthcare is designed to disrupt cell or tissue samples for protein extraction.

2-D Clean-Up Kit from GE Healthcare is designed to prepare samples that would otherwise produce poor 2-D results.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..