Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

GE28-9924-74

HiScreen Capto Blue

Cytiva 28-9924-74, pack of 1 column

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
23151817
NACRES:
NA.56

Confezionamento

pack of 1 column

Produttore/marchio commerciale

Cytiva 28-9924-74

Parametri

1.2 ml/min - 2.3 ml/min flow rate
44 psi

Dimensioni del letto

7.7 mm × 100 mm

Volume del letto

4.7 mL

Capacità

~25 mg binding capacity(human serum albumin/ml medium)

Temperatura di conservazione

2-8°C

Descrizione generale

HiScreen™ columns are part of the process development platform available from Cytiva. The columns are prepacked with a range of BioProcess chromatography media (resins) and designed for method optimization and parameter screening. HiScreen™ columns have small bed volumes (4.7 ml), reducing the cost of sample and buffer consumption. The media used in HiScreen™ columns are also available in other prepacked formats and as bulk packs, for all scales of work from development and pilot studies to routine production.

Applicazioni

HiScreen Capto Blue is prepacked with the base matrix Capto to which Cibacron Blue 3G is covalently bound via a hydrophilic spacer immobilized with a stable amine bond. Capto Blue is highly chemically stable and has a more rigid Agarose base matrix than Blue Sepharose 6 Fast Flow. This allows the use of faster flow rates and larger sample volumes, leading to higher throughput and improved process economy. The application area is the same as for Blue Sepharose Fast FLow (e.g., purification of albumin, enzymes including NAD+ and NADP+, coagulation factors, interferons, and related Proteins). The main benefit of Capto Blue compared to Blue Sepharose 6 Fast FLow is its improved chemical stability provided with a new coupling chemistry involving a spacer arm. It tolerates repeated cleaning-in-place and sanitization at both high and Low pH as well as autoclaving. Also the leakage of Cibacron Blue is reduced as compared to Blue Sepharose 6 Fast Flow.

Caratteristiche e vantaggi

  • Prepacked with Capto Blue
  • Excellent for method optimization and parameter screening due to the 10 cm bed height
  • Easily connected in series to achieve 20 cm bed height
  • Small bed volume for fast results and minimal sample/buffer consumption
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same flow velocity

Stoccaggio e stabilità

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

Risultati analitici

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Altre note

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

Note legali

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva
Sepharose is a trademark of Cytiva

Prodotti correlati

N° Catalogo
Descrizione
Determinazione del prezzo

Pittogrammi

Flame

Avvertenze

Warning

Indicazioni di pericolo

Codice della classe di stoccaggio

3 - Flammable liquids


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Protocolli

This page shows how purify or remove albumin with Blue Sepharose and Capto Blue from GE Healthcare.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.