12015196001
Roche
Lumi-LightPLUS Western Blotting Substrate
pkg of 100 mL (1,000 cm2 membrane)
Sinonimo/i:
western blotting substrate
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Confezionamento
pkg of 100 mL (1,000 cm2 membrane)
Livello qualitativo
Produttore/marchio commerciale
Roche
Condizioni di spedizione
wet ice
Temperatura di conservazione
2-8°C
Descrizione generale
As the technology for quantifying chemiluminescence advances, the substrates for chemiluminescence must also advance. For instance, the light emission of conventional enhanced luminol substrates substantially decreases within 30 minutes. In contrast, the chemiluminescence signal of the Lumi-LightPLUS substrate persists for more than nine hours, and since exposures of only a few minutes are necessary, multiple exposures can be taken. Additionally, the ability to take extended exposures allows the detection of rare proteins, or higher dilutions of antigen or antibody to be used. The emission wavelength of the Lumi-LightPLUS substrate is 425 nm.
Comparison of Lumi-Light Substrate and Lumi-Light PLUS Substrate
Lumi-Light Substrate Lumi-LightPLUS Substrate
Sensitivity 10-50 pg antigen 1-5 pg antigen
Pimary Antibody Dilution Dilute up to 10-fold more compared to colorimetric detection Dilute up to 100-fold more compared to colorimetric detection
Signal Stability >3 hours (enhance signal with a 30-minute incubation) > 9 hours (enhance signal with a 30-minute incubation)
Number of tests: The reagent is sufficient for 10 blots, each with a size of 10 cm x 10 cm.
Sensitivity: Depending on the affinity of the primary antibody, 1 - 5 pg of antigen can be detected in research studies.
Storage/stability: The Lumi-LightPLUS substrate components are stable at +2 to +8°C until the expiration date printed on the label. Components are shipped at +15 to +25°C.
Comparison of Lumi-Light Substrate and Lumi-Light PLUS Substrate
Lumi-Light Substrate Lumi-LightPLUS Substrate
Sensitivity 10-50 pg antigen 1-5 pg antigen
Pimary Antibody Dilution Dilute up to 10-fold more compared to colorimetric detection Dilute up to 100-fold more compared to colorimetric detection
Signal Stability >3 hours (enhance signal with a 30-minute incubation) > 9 hours (enhance signal with a 30-minute incubation)
Number of tests: The reagent is sufficient for 10 blots, each with a size of 10 cm x 10 cm.
Sensitivity: Depending on the affinity of the primary antibody, 1 - 5 pg of antigen can be detected in research studies.
Storage/stability: The Lumi-LightPLUS substrate components are stable at +2 to +8°C until the expiration date printed on the label. Components are shipped at +15 to +25°C.
Applicazioni
Lumi-LightPLUS Western Blotting Substrate has been used in western blotting.
Lumi-LightPLUS Western Blotting Substrate is for the chemiluminescent detection of antigens blotted on membranes using horseradish peroxidase-conjugated secondary antibodies. It can be used for very sensitive detection of any antigen blotted on a PVDF Western Blotting Membrane or nitrocellulose membrane.
Lumi-LightPLUS Western Blotting Substrate is suited for high-sensitivity western blotting, especially when quantification is required. The chemiluminescent signal persists for more than 9 hours, allowing multiple exposures to be taken.
Lumi-LightPLUS Western Blotting Substrate is suited for high-sensitivity western blotting, especially when quantification is required. The chemiluminescent signal persists for more than 9 hours, allowing multiple exposures to be taken.
Caratteristiche e vantaggi
- Detect rare proteins. Detect antigen in the range of 1 - 5 pg.
- Take multiple exposures. The signal is stable for more than nine hours after substrate addition.
- Save sample material. Lumi-LightPLUS substrate detects less than 5 pg-amounts of antigen.
- Save valuable resources. Dilute primary antibody 10- to 100-fold more than with colorimetric detection systems.
- Benefit from easy preparation. Simply mix the two Lumi-Light components in a 1:1 ratio.
Confezionamento
1 kit containing 2 components
Qualità
Each lot is function tested using mouse or rabbit primary antibodies.
Nota sulla preparazione
Stabilizers: proteinaceous stabilizers
Working concentration: The working concentration of conjugate depends on application and substrate.
The following concentrations should be taken as a guideline:
Working solution: Preparation of Additional Reagents and Solutions
The table inside the package insert describes the preparation of working solutions. Volumes are designed for a membrane of 10x10 cm. If larger membranes are used, volumes have to be scaled up. For reproducible results, equilibrate all solutions to room temperature before use.
Note: Do not use Azide to stabilize the solutions against microbial growth, as azide irreversibly inhibits horseradish peroxidase.
Working concentration: The working concentration of conjugate depends on application and substrate.
The following concentrations should be taken as a guideline:
- Dot blot: 50 mU/ml
- ELISA: 25 mU/ml
- Western blot: 50 mU/ml
Working solution: Preparation of Additional Reagents and Solutions
The table inside the package insert describes the preparation of working solutions. Volumes are designed for a membrane of 10x10 cm. If larger membranes are used, volumes have to be scaled up. For reproducible results, equilibrate all solutions to room temperature before use.
Note: Do not use Azide to stabilize the solutions against microbial growth, as azide irreversibly inhibits horseradish peroxidase.
Altre note
For life science research only. Not for use in diagnostic procedures.
Solo come componenti del kit
N° Catalogo
Descrizione
- Lumi-LightPLUS Luminol/Enhancer Solution
- Lumi-LightPLUS Stable Peroxide Solution
Codice della classe di stoccaggio
12 - Non Combustible Liquids
Classe di pericolosità dell'acqua (WGK)
WGK 1
Punto d’infiammabilità (°F)
does not flash
Punto d’infiammabilità (°C)
does not flash
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Serum-Induced Differentiation of Glioblastoma Neurospheres Leads to Enhanced Migration/Invasion Capacity That Is Associated with Increased MMP9
PLoS ONE (2015)
Naunyn-Schmiedeberg's archives of pharmacology, 385(9), 875-882 (2012-06-13)
β(3)-Adrenoceptors are a promising drug target for the treatment of urinary bladder dysfunction, but knowledge about their expression at the protein level and their functional role is limited, partly due to a lack of well validated tools. As many antibodies
Thioredoxin-1 protects against androgen receptor-induced redox vulnerability in castration-resistant prostate cancer
Nature Communications, 8(1), 1204-1204 (2017)
Ataxia telangiectasia mutated (ATM) inhibition transforms human mammary gland epithelial cells
The Journal of Biological Chemistry, 285(17), 13092-13106 (2010)
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.