Passa al contenuto
Merck
Tutte le immagini(3)

Key Documents

HAIAB-10K

Millipore

MILLIPLEX® Human Autoimmune Autoantibody Panel

Milliplex®

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
12161503
eCl@ss:
32161000
NACRES:
NA.47

Reattività contro le specie

human

Produttore/marchio commerciale

Milliplex®

tecniche

multiplexing: suitable

Metodo di rivelazione

fluorometric (Luminex xMAP)

Descrizione generale

Autoantibody formation is principal to the pathogenesis of a variety of autoimmune diseases. Dysregulated apoptosis and the subsequent defective clearance of cellular debris leads to the exposure of autoantigens and the generation of autoantibodies. The presence of autoantibodies may indicate disease activity, prognosis, and clinical associations related to a variety of autoimmune diseases. These autoimmune diseases include, but are not limited to, Sjögren′s Syndrome, Systemic Lupus Erythematosus, Mixed Connective Tissue Disease, Systemic Sclerosis, CREST syndrome, Polymyositis/Dermatomyositis, Vasculitis, Anti-Phospholipid Syndrome, and various overlap syndromes of these diseases.

MILLIPLEX® Human Autoimmune Autoantibody Bead Panel is a 20-plex kit to be used for the simultaneous detection and profiling of any or all of the following analytes in serum and plasma samples: Anti-C1q, Anti-Centromere Protein A (CENP-A), Anti-Centromere Protein B (CENP-B), Anti-β 2-Glycoprotein, Anti-Jo-1, Anti-Ku, Anti-Mi-2, Anti-Myeloperoxidase, Anti-Proliferating cell nuclear antigen A (PCNA), Anti-Alanyl-tRNA synthetase (PL-12), Anti-PM/Scl-100, Anti-Proteinase 3, Anti-Ribosomal P, Anti-Ribonucleoprotein (RNP), Anti-RNP/Smith (RNP/Sm), Anti-Scl-70, Anti-Sm, Anti-Sjögren′s Syndrome-related antigen B/La (SSB/La), Anti-Anti-Sjögren′s Syndrome-related antigen A/Ro52 kDa (SSA/Ro52), Anti-Sjögren′s Syndrome-related antigen A/Ro60 kDa (SSA/Ro60). This panel includes 4 assay control beads as part of the base kit format. From our single to multiplex biomarker solutions, we partner with you to design, develop, analytically verify, and build the most comprehensive library available for autoantibody detection.

Panel Type: Immune Response

Specificità

Cross Reactivty
Samples were incubated with no antigen, irrelevant antigen, or specific antigen. Incubation with a partcular antigen led to selective abrogation of the reactivity, while reactivity was unaffected by the irrelevant antigen.

Applicazioni

  • Analytes: β2-Glycoprotein, C1q, CENP-B (Centromere Protein B), CENP-A (Centromere Protein A), Jo-1, Ku, Mi-2, Myeloperoxidase (MPO), PCNA (Proliferating Cell Nuclear Antigen A), PL-12 (Alanyl-tRNA synthetase), PM/Scl 100, Proteinase 3, RNP (Ribonucleoprotein), RNP/Smith (RNP/Sm), Ribosomal P, Scl-70, Sm, SSB/La (Sjögren′s Syndrome-related antigen B/La), SSA/Ro60 (Sjögren′s Syndrome-related antigen A/Ro60 kDa), SSA/Ro52 (Sjögren′s Syndrome-related antigen A/Ro52 kDa)
  • This is a qualitative assay.
  • Four assay control beads are included in the base kit.
  • Recommended Sample type: serum and plasma.
  • Assay Run Time: Overnight
  • Research Category: Category Inflammation & Immunology
  • Research Subcategory: Autoimmune disease, Inflammation, Immune Response, Immune Disorders

Caratteristiche e vantaggi

Design your multiplex kit by choosing available analytes within this panel.

Confezionamento

96 well plate
Everything you need in a single kit.

Stoccaggio e stabilità

Recommended storage for kit components is 2 - 8°C.

Note legali

MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pittogrammi

Exclamation markEnvironment

Avvertenze

Warning

Indicazioni di pericolo

Classi di pericolo

Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1

Codice della classe di stoccaggio

12 - Non Combustible Liquids

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Jieun Kwon et al.
The ocular surface, 18(1), 80-97 (2019-10-14)
To investigate the role of Anti-Citrullinated Protein autoantibodies (ACPAs) in the pathology of dry eye disease (DED) and the therapeutic potential of pooled human immune globulin-eye drops in these patients. We investigated the presence of citrullinated proteins and ACPAs in

Contenuto correlato

Multiplex analysis of autoantibodies, such as MILLIPLEX® multiplex assays, helps advance research by detecting multiple autoantibodies like cytokine autoantibodies, autoimmune autoantibodies, and cancer autoantibodies at once to give researchers a full picture of analyte concentrations.

Immunology multiplex assays, like MILLIPLEX® assays, allow researchers to investigate more immune biomarkers simultaneously, saving time and resources. This is especially critical to immunology research, where numerous analytes play a role in different pathways.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.