Direkt zum Inhalt
Merck

182028

Sigma-Aldrich

Poly(ethylenoxid)

average MV 600,000 (nominal), powder, hydroxyl, BHT as inhibitor

Synonym(e):

PEO

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
(-CH2CH2O-)n
CAS-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352104
PubChem Substanz-ID:
NACRES:
NA.23

Produktbezeichnung

Poly(ethylenoxid), average Mv 600,000 (nominal), powder

Form

powder

Qualitätsniveau

Mol-Gew.

average Mv 600,000 (nominal)

Enthält

200-500 ppm BHT as inhibitor

Viskosität

4,500-8,800 cP, 5 % in H2O(25 °C, Brookfield)(lit.)

Übergangstemp.

Tm 65 °C

Ω-Ende

hydroxyl

α-Ende

hydroxyl

Anwendung(en)

battery manufacturing

SMILES String

[H]OCCO

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2

InChIKey

LYCAIKOWRPUZTN-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Poly(ethylenoxid)(PEO) ist ein nichtionisches wasserlösliches Polymer mit hoher Molekülmasse. Es bildet einGel bei der Hydrierung und weist eine gute Quellkapazität auf. PEO-Polymere sind nichttoxischund werden verbreitet in Arzneimittelabgabesystemen verwendet, um die Arzneimittellöslichkeit zu verbessern.

Anwendung

Poly(ethylenoxid) kann zum Herstellen von Folgendem verwendet werden:
  • Bioabsorbierbare und injizierbare Hydrogele für die verzögerte Arzneimittelfreisetzung.
  • PEO/Graphenoxid-Verbundmaterial-Elektrolytmembran für Brennstoffzellen.
  • Poly(ethylenoxid)-b-poly(ε-caprolacton)(PEO-b-PCL)-Diblockcopolymer. Losartankalium-eingekapseltes (PEO-b-PCL) Copolymer kann als Arzneimittelträger verwendet werden.

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 1

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

D D Smyth et al.
Cardiovascular drugs and therapy, 4(1), 297-300 (1990-02-01)
Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in
M Patel Geeta et al.
Current drug delivery, 6(2), 159-165 (2009-05-20)
Carbamazepine indicated for the control of epilepsy, undergoes extensive hepatic first-pass metabolism after oral administration. A vaginal dosage form of carbamazepine is not commercially available. Conventional suppository having poor retention in the vaginal tract, as they are removed in a
P I Polimeni et al.
Journal of cardiovascular pharmacology, 14(3), 374-380 (1989-09-01)
The acute hemodynamic effects of an intravenously (i.v.) injected poly(ethylene oxide), Polyox WSR N-60K (dose 50 mg/kg), were studied in the open-chest rat anesthetized with sodium pentobarbital. The injectate is one of four drag-reducing polymers known to augment in vitro
I L Konorova et al.
Patologicheskaia fiziologiia i eksperimental'naia terapiia, (4)(4), 7-9 (1991-07-01)
The search for antiaggregatory compounds is undertaken, as a rule, under in vitro conditions which do not reflect the dynamics of the real process. The present work deals with study of the peculiarities of the development of the collagen induced

Artikel

Progress in biotechnology fields such as tissue engineering and drug delivery is accompanied by an increasing demand for diverse functional biomaterials. One class of biomaterials that has been the subject of intense research interest is hydrogels, because they closely mimic the natural environment of cells, both chemically and physically and therefore can be used as support to grow cells. This article specifically discusses poly(ethylene glycol) (PEG) hydrogels, which are good for biological applications because they do not generally elicit an immune response. PEGs offer a readily available, easy to modify polymer for widespread use in hydrogel fabrication, including 2D and 3D scaffold for tissue culture. The degradable linkages also enable a variety of applications for release of therapeutic agents.

Devising biomaterial scaffolds that are capable of recapitulating critical aspects of the complex extracellular nature of living tissues in a threedimensional (3D) fashion is a challenging requirement in the field of tissue engineering and regenerative medicine.

Global Trade Item Number

SKUGTIN
182028-500G4061838755605
182028-250G4061838755599
182028-500G-PM4065270170316
182028-5G4061838755612

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.