Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

CRM68471

Supelco

Flucythrinate

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Sinônimo(s):

α-Cyano-3-phenoxybenzyl 4-difluoromethoxy-α-isopropylphenylacetate

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula empírica (Notação de Hill):
C26H23F2NO4
Número CAS:
Peso molecular:
451.46
Número MDL:
Código UNSPSC:
41116107
NACRES:
NA.24

grau

certified reference material
TraceCERT®

Nível de qualidade

linha de produto

TraceCERT®

prazo de validade

limited shelf life, expiry date on the label

fabricante/nome comercial

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

temperatura de armazenamento

2-8°C

cadeia de caracteres SMILES

CC(C)C(C(=O)OC(C#N)c1cccc(Oc2ccccc2)c1)c3ccc(OC(F)F)cc3

InChI

1S/C26H23F2NO4/c1-17(2)24(18-11-13-21(14-12-18)32-26(27)28)25(30)33-23(16-29)19-7-6-10-22(15-19)31-20-8-4-3-5-9-20/h3-15,17,23-24,26H,1-2H3

chave InChI

GBIHOLCMZGAKNG-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com
Flucythrinate is a synthetic a-cyano pyrethroid insecticide that acts as a voltage gated sodium channel agonist. It finds its use to provide protection against a variety of sucking insects, beetles, and lepidoptera in cotton and pome fruits.
Flucythrinate is not approved for its use in the European Union (EU) as per the Commission Regulation (EC) No 2076/2002 of 20th November 2002 as a plant protection agent under the Regulation (EC) No. 1107/2009, repealing the directive 91/414/EEC. Flucythrinate is measured and reported along with other mixtures of its constituent isomers (sum of isomers). But a default maximum residue limit (MRL) of 0.01 mg/kg and 0.02 mg/kg is applicable for its presence in fresh/frozen fruits and tree nuts respectively according to Reg. (EU) 2015/868.

Aplicação

The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
The methiocarb CRM may also find use as given below:
  • Development of a class selective enzyme-linked immunosorbent assay (ELISA) to screen a-cyano pyrethroids and their metabolites
  • Comparison between two sample preparation techniques-dispersive liquid-liquid microextraction (DLLME) and QuEChERS-DLLME, followed by gas chromatography-electron capture detection (GC-ECD) for the determination of 10 pyrethroids from different fruit juice samples
  • Multi-residue analysis of 133 pesticide residues in chenpi samples using a modified QuEChERS method and gas chromatography-tandem mass spectrometry (GC-MS/MS)
  • Simultaneous determination of 78 pesticides in black tea samples using multi-walled carbon nanotubes (MWCNTs) for dispersive solid phase extraction (d-SPE) accompanied by quantification with gas chromatography-tandem mass spectrometry (GC-MS/MS)
  • Development of a method based on gas chromatography-mass spectrometry (GC-MS) in negative chemical ionization mode to determine 17 pyrethroid residues in garlic, onion, spring onion, and chili samples
  • Development and validation of a method for multi-residue analysis of 124 pesticides in rice samples using modified QuEChERS extraction and gas chromatography-tandem mass spectrometry (GC-MS/MS)

Informações legais

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Palavra indicadora

Danger

Frases de perigo

Classificações de perigo

Acute Tox. 3 Oral - Acute Tox. 4 Inhalation - Aquatic Acute 1 - Aquatic Chronic 1 - Flam. Liq. 3

Código de classe de armazenamento

3 - Flammable liquids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

113.0 °F

Ponto de fulgor (°C)

45 °C


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Julia Ortmann et al.
ALTEX, 39(1), 82-94 (2021-08-08)
The photomotor response (PMR) of zebrafish embryos, a light pulse-triggered undirected movement, is known to be altered by neuroactive chemicals. Here, we developed an approach for data analysis of the distribution of PMR movement activities along the time axis; differences
Xue Hou et al.
Food chemistry, 153, 121-129 (2014-02-05)
A modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method using multi-walled carbon nanotubes (MWCNTs) as a dispersive solid phase extraction (d-SPE) absorbent was established for analysis of 78 pesticide residues in tea. A 6 mg MWCNT sample was
Yaohai Zhang et al.
Food chemistry, 159, 367-373 (2014-04-29)
Dispersive liquid-liquid microextraction (DLLME) sample preparation and the quick, easy, cheap, effective, rugged and safe (QuEChERS) method combined with DLLME were developed and compared for the analysis of ten pyrethroids in various fruit juices using gas chromatography-electron capture detection (GC-ECD).
Xue Hou et al.
Food chemistry, 138(2-3), 1198-1205 (2013-02-16)
A modified QuEChERS method for simultaneous determination of 124 pesticide residues in rice was established and validated. The rice samples were initially extracted with acetonitrile (MeCN), and the targeted pesticides were purified following the dispersive solid phase extraction (d-SPE) cleanup

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica