PROTIA
ProteoPrep® Immunoaffinity Albumin & IgG Depletion Kit
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Descrição geral
ProteoPrep® Immunoaffinity Albumin and IgG Depletion Kit might be a useful tool for novel biomarker discovery.
The ProteoPrep® Immunoaffinity medium in the prepacked spin columns is a mixture of two-beaded media containing recombinantly expressed, small single-chain antibody ligands, resulting in low non-specific binding and high capacity. The ProteoPrep Immunoaffinity Albumin and IgG Depletion Kit has been designed to specifically remove albumin and IgG from human serum (25-50μL) in preparation of samples for proteomics analysis, two-dimensional electrophoresis (2DE) or liquid chromatography (LC). This kit is also effective in depleting albumin and IgG from mouse and guinea pig serum.
Aplicação
ProteoPrep® Immunoaffinity Albumin & amp; IgG Depletion Kit has been used in:
- umbilical cord serum proteomics
- human plasma (HP) proteomics
- proteomic profile-based screening of potential protein biomarkers in the urine of patients with nephrotic syndrome
Características e benefícios
- High Capacity removes more interfering abundant proteins
- High Specifity ensures you see an accurate and more complete proteome
- Buffer systems are compatible with 2 dimensional electrophoresis so there are no intermediate time consuming steps that might result in protein loss
Informações legais
ProteoPrep is a registered trademark of Merck KGaA, Darmstadt, Germany
Palavra indicadora
Warning
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 4 Oral - Aquatic Chronic 2 - Carc. 2 - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - Skin Sens. 1
Código de classe de armazenamento
10 - Combustible liquids
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Molecular medicine reports, 16(5), 6276-6284 (2017-08-30)
Nephrotic syndrome is not a single disease; rather, it is a term for numerous diseases and pathological types. Renal biopsy is of use in determining the diagnosis and prognosis, and for guiding treatment; however, the use of this intervention is
Analytical and bioanalytical chemistry, 411(3), 777-786 (2018-11-25)
High- and low-density lipoproteins (HDL and LDL) are attractive targets for biomarker discovery. However, ultracentrifugation (UC), the current methodology of choice for isolating HDL and LDL, is tedious, requires large sample volume, results in sample loss, and does not readily
Journal of cardiovascular pharmacology, 65(6), 611-619 (2015-02-26)
Inclacumab, a novel monoclonal antibody against P-selectin in development for the treatment and prevention of atherosclerotic cardiovascular diseases, was administered in an ascending single-dose study as intravenous infusion to evaluate safety, pharmacokinetics, and pharmacodynamics. Fifty-six healthy subjects were enrolled in
Molecular & cellular proteomics : MCP, 14(12), 3118-3131 (2015-09-27)
The inter-α-trypsin inhibitor complex is a macromolecular arrangement of structurally related heavy chain proteins covalently cross-linked to the chondroitin sulfate (CS) chain of the proteoglycan bikunin. The inter-α-trypsin inhibitor complex is abundant in plasma and associated with inflammation, kidney diseases
Analytical and bioanalytical chemistry, 407(3), 661-667 (2014-12-01)
In this manuscript we briefly describe bipolar disorder (a depressive and manic mental disease), its classification, its effects on the patient, which sometimes include suicidal tendencies, and the drugs used for treatment. We also address the status quo with regard
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica