Pular para o conteúdo
Merck
Todas as fotos(8)

Key Documents

793558

Sigma-Aldrich

Sodium iodide

anhydrous, free-flowing, Redi-Dri, ReagentPlus®, ≥99%

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
NaI
Número CAS:
Peso molecular:
149.89
Número CE:
Número MDL:
Código UNSPSC:
12352302
ID de substância PubChem:
NACRES:
NA.21

grau

anhydrous

Nível de qualidade

densidade de vapor

>1 (vs air)

linha de produto

ReagentPlus®
Redi-Dri

Ensaio

≥99%

forma

powder

qualidade

free-flowing

Impurezas

≤1.0% water

pH

6-9 (20 °C, 50 g/L)

pf

661 °C (lit.)

cadeia de caracteres SMILES

[Na+].[I-]

InChI

1S/HI.Na/h1H;/q;+1/p-1

chave InChI

FVAUCKIRQBBSSJ-UHFFFAOYSA-M

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Sodium iodide is an inorganic sodium salt. It is used as an iodinating agent in organic synthesis to prepare various iodine-containing compounds. It is used in the conversion of alkyl halides and sulfonates into alkyl iodides and aryl iodides via nucleophilic displacement reactions. Additionally, sodium iodide is also used in combination with oxidizing agents for the iodination of organoboranes, phenols, and aromatic compounds.

Aplicação

Sodium iodide can be used as an iodine precursor salt to synthesize semi-organic nonlinear optical single crystal of bis thiourea sodium iodide (BTSI) via slow evaporation solvent technique.

Informações legais

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany
Redi-Dri is a trademark of Sigma-Aldrich Co. LLC

Pictogramas

Exclamation mark

Palavra indicadora

Warning

Frases de perigo

Classificações de perigo

Eye Irrit. 2

Código de classe de armazenamento

13 - Non Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

P E N Braad et al.
Physics in medicine and biology, 60(13), 5297-5312 (2015-06-26)
Peri-therapeutic (124)I-PET/CT is of interest as guidance for radioiodine therapy. Unfortunately, image quality is complicated by dead time effects and increased random coincidence rates from high (131)I-activities. A series of phantom experiments with clinically relevant (124)I/(131)I-activities were performed on a
Kohei Sano et al.
Biochemical and biophysical research communications, 464(3), 820-825 (2015-07-15)
Photoacoustic (PA) imaging is an attractive imaging modality for sensitive and depth imaging of biomolecules with high resolution in vivo. The aim of this study was to evaluate the effectiveness of an anti-epidermal growth factor receptor (EGFR) monoclonal antibody (panitumumab; Pan)
Mohamed Touati et al.
Leukemia & lymphoma, 56(2), 332-341 (2014-04-29)
Finding new prognostic factors to identify patients with Hodgkin lymphoma (HL) at risk of treatment resistance or relapse remains challenging in daily practice. We evaluated the relationship between CD68 expression, interim positron emission tomography (iPET) results and outcome in 158
Anke de Vries et al.
Investigative radiology, 50(4), 297-304 (2015-01-01)
The objective of this study was to investigate the feasibility and the accuracy of spectral computed tomography (spectral CT) to determine the tissue concentrations and localization of high-attenuation, iodine-based contrast agents in mice. Iodine tissue concentrations determined with spectral CT
Marlein Miranda Cona et al.
International journal of oncology, 44(3), 819-829 (2013-12-25)
Iodine-131‑labeled monoiodohypericin (131I‑Hyp) is a necrosis avid compound used as a complementary anticancer agent. Herein, the biodistribution in rats with re-perfused partial liver infarction (RPLI) was used to estimate its human internal radiation dosimetry. Iodine-123‑labeled monoiodohypericin (123I-Hyp) as a safer

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica