MHSTCMAG-70K
MILLIPLEX® Mouse High Sensitivity T Cell Panel - Immunology Multiplex Assay
Simultaneous analyze low levels of cytokine and chemokine biomarker with the High Sensitivity Bead-Based Multiplex Assays using the Luminex technology, in mouse serum, plasma and cell culture samples.
Sinônimo(s):
Luminex® Mouse Immunology Panel, Millipore Mouse Immunology Panel, Mouse Immunology Protein Multiplex Assay
About This Item
Produtos recomendados
Nível de qualidade
reatividade de espécies
mouse
fabricante/nome comercial
Milliplex®
assay range
accuracy: 82-102%
sensitivity: 0.26-11.14 pg/mL
standard curve range: 0.10-400 pg/mL
(IL-4)
standard curve range: 0.49-2,000 pg/mL
(IFNγ)
standard curve range: 0.49-2,000 pg/mL
(IL-17A)
standard curve range: 0.49-2,000 pg/mL
(IL-7)
standard curve range: 0.49-2,000 pg/mL
(TNFα)
standard curve range: 0.73-3,000 pg/mL
(KC/GROα/CXCL1)
standard curve range: 0.98-4,000 pg/mL
(IL-2)
standard curve range: 0.98-4,000 pg/mL
(IL-5)
standard curve range: 0.98-4,000 pg/mL
(IL-6)
standard curve range: 1.34-5,500 pg/mL
(IL-10)
standard curve range: 2.93-12,000 pg/mL
(IL-12 (p70))
standard curve range: 3.17-13,000 pg/mL
(LIX)
standard curve range: 3.42-14.000 pg/mL
(IL-13)
standard curve range: 3.91-16,000 pg/mL
(IL-1α)
standard curve range: 3.91-16,000 pg/mL
(IL-1β)
standard curve range: 3.91-16,000 pg/mL
(MCP-1/CCL2)
standard curve range: 6.1-25,000 pg/mL
(GM-CSF)
standard curve range: 7.32-30,000 pg/mL
(MIP-2/CXCL2)
inter-assay cv: <15%
intra-assay cv: <10%
técnica(s)
multiplexing: suitable
método de detecção
fluorometric (Luminex xMAP)
Condições de expedição
ambient
Categorias relacionadas
Descrição geral
Low levels of inflammation are involved in many clinical and sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.
Panel Type: Cytokines/Chemokines
Especificidade
There is no detectable cross-reactivity within the panel.
Aplicação
- Analytes: GM-CSF, IFNγ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-10, IL-12 (p70), IL-13, IL-17A, KC/CXCL1, LIX, MCP-1, MIP-2, TNF-α
- Recommended Sample type: serum, plasma, tissue culture or other media
- Recommended Sample dilution: neat or 1:2 diluted serum or plasma
- Assay Run Time: Overnight
- Research Category: Inflammation & Immunology
- Research Subcategory: Immune Response Metabolic Disorders Chronic Inflammatory Disease Cardiovascular Disease
Características e benefícios
Armazenamento e estabilidade
Outras notas
Informações legais
Exoneração de responsabilidade
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Órgãos-alvo
Respiratory Tract
Código de classe de armazenamento
10 - Combustible liquids
Classe de risco de água (WGK)
WGK 3
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica