KHGEA2ZTH1
Cápsula Millipore Express® SHC, Opticap® XLT
Opticap® XLT 20, inlet connection diam. 1.5 in., pore size 0.5/0.2 μm, cartridge nominal length 20 in. (50 cm)
Sinônimo(s):
Autoclavable Opticap XLT 20 Millipore Express SHC 0.5/0.2 μm TC/HB 1pk w/gauge port
About This Item
Produtos recomendados
Materiais
polyethersulfone
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
polysulfone
silicone seal
Nível de qualidade
conformidade reg.
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
esterilidade
non-sterile
Compatibilidade de esterilização
autoclavable compatible
linha de produto
Opticap® XLT 20
Características
hydrophilic
fabricante/nome comercial
Millipore Express®
Parâmetros
1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 bar max. differential pressure (15 psi) at 80 °C (Forward)
2.75 bar max. inlet pressure (40 psi) at 60 °C
2100 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 °C
5500 mbar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure
técnica(s)
sterile filtration: suitable
Comprimento
61.1 cm (24.0 in.)
Largura
7.8 in.
comprimento nominal do cartucho
20 in. (50 cm)
Diâmetro
19.8 cm (7.8 in.)
área de filtração
0.98 m2
diâm. conexão de entrada
1.5 in.
diam. conexão de saída
5/8 in.
Impurezas
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matriz
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
ponto de bolha
≥4000 mbar (58 psig), air with water at 23 °C
conector
3/4 in. gauge port (T-Line Side)
inlet sanitary flange
outlet hose barb
1/4 in. vent hose barb (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 16 mm (5?8 in.) Hose Barb Outlet)
Descrição geral
Embalagem
Outras notas
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Nota de preparo
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Nota de análise
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 40 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informações legais
Exoneração de responsabilidade
Não está encontrando o produto certo?
Experimente o nosso Ferramenta de seleção de produtos.
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica