P-114
PEth 16:0/18:1 solution
1.0 mg/mL in methanol (as free phosphate), certified reference material, ampule of 1 mL, Cerilliant®
About This Item
Produtos recomendados
grau
certified reference material
Nível de qualidade
forma
liquid
Características
Snap-N-Spike®/Snap-N-Shoot®
embalagem
ampule of 1 mL
fabricante/nome comercial
Cerilliant®
concentração
1.0 mg/mL in methanol (as free phosphate)
técnica(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
aplicação(ões)
forensics and toxicology
formato
single component solution
temperatura de armazenamento
−70°C
cadeia de caracteres SMILES
CCOP(OC[C@H](OC(CCCCCCCC=CCCCCCCCC)=O)COC(CCCCCCCCCCCCCCC)=O)([O-])=O.CCCC[N+](CCCC)(CCCC)CCCC
InChI
1S/C39H75O8P.C16H36N/c1-4-7-9-11-13-15-17-19-20-22-24-26-28-30-32-34-39(41)47-37(36-46-48(42,43)45-6-3)35-44-38(40)33-31-29-27-25-23-21-18-16-14-12-10-8-5-2;1-5-9-13-17(14-10-6-2,15-11-7-3)16-12-8-4/h19-20,37H,4-18,21-36H2,1-3H3,(H,42,43);5-16H2,1-4H3/q;+1/p-1/b20-19-;/t37-;/m1./s1
chave InChI
QDVSIAATLNPVDB-VYMFHCNISA-M
Descrição geral
Aplicação
- Alcohol consumption biomarker analysis: PEth 16:0/18:1 is used as a biomarker in whole blood and hair for monitoring alcohol use, proving essential in both clinical settings and research studies focused on substance abuse and its physiological impacts (Dumitrascu et al., 2024).
- Diagnostic tool in traffic safety: Its application in dried blood samples from drivers involved in traffic accidents makes PEth 16:0/18:1 crucial for forensic science, aiding in the assessment of alcohol consumption as a factor in accidents (Daglioglu et al., 2022).
- Method development in chromatography: PEth 16:0/18:1 is vital for developing methods to quantify phosphatidylethanol concentrations in novel sampling devices, enhancing the reliability of alcohol screening tests (Jett et al., 2023).
- Advances in lipid chromatography: This compound is instrumental in refining chromatographic techniques to avoid the co-elution of phosphatidylethanols with unwanted phospholipids, improving the accuracy of lipidomics analyses (Maria et al., 2022).
- Clinical biomarker validation: The validation of liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring erythrocyte PEth 16:0/18:1 emphasizes its role in clinical diagnostics, particularly in the accurate and sensitive detection of alcohol intake levels (White et al., 2022).
Informações legais
produto relacionado
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Órgãos-alvo
Eyes
Código de classe de armazenamento
3 - Flammable liquids
Classe de risco de água (WGK)
WGK 2
Ponto de fulgor (°F)
49.5 °F - closed cup
Ponto de fulgor (°C)
9.7 °C - closed cup
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica