P-098
Psilocin solution
1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Produtos recomendados
grau
certified reference material
Nível de qualidade
forma
liquid
Características
(Snap-N-Spike®)
embalagem
ampule of 1 mL
fabricante/nome comercial
Cerilliant®
drug control
Narcotic Licence Schedule D (Switzerland); psicótropo (Spain); Decreto Lei 15/93: Tabela IIA (Portugal)
concentração
1.0 mg/mL in acetonitrile
técnica(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
aplicação(ões)
forensics and toxicology
formato
single component solution
temperatura de armazenamento
−70°C
cadeia de caracteres SMILES
CN(C)CCc1c[nH]c2cccc(O)c12
InChI
1S/C12H16N2O/c1-14(2)7-6-9-8-13-10-4-3-5-11(15)12(9)10/h3-5,8,13,15H,6-7H2,1-2H3
chave InChI
SPCIYGNTAMCTRO-UHFFFAOYSA-N
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
Descrição geral
Psilocin is a natural psychoactive compound that belongs to the class of tryptamine alkaloids. It is one of the main hallucinogenic compounds obtained from widely known “magic mushrooms”― Psilocybe, Panaeolus, and Conocybe. Known by street names such as Shrooms, Boomers, or Musk, psilocin has effects similar to LSD and DMT.
Aplicação
- Development of an ultra-high-performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method to quantify psilocybin and psilocin in samples of seized hallucinogenic mushrooms and hair obtained from accused users
- Multi-residue analysis of psilocin, psilocybin, mescaline, N,N-dimethyltryptamine, and salvinorin A in human hair samples using ultra-high-pressure liquid chromatography (UHPLC) combined with tandem mass spectrometry (MS/MS)
- Liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) analysis of psilocin, bufotenine, lysergic acid diethylamide, and its metabolites in human plasma, serum, and urine samples following their solid phase extraction (SPE)
- Quantification of psilocin from plasma samples by solid phase extraction in mixed mode and liquid chromatography-electrospray ionization-tandem mass spectrometry
- Urine analysis for psilocin and muscimol using single drop microextraction combined with capillary electrophoresis (SDME-CE) without any sample clean-up step
Características e benefícios
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Produtos recomendados
Informações legais
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Código de classe de armazenamento
3 - Flammable liquids
Classe de risco de água (WGK)
WGK 2
Ponto de fulgor (°F)
35.6 °F - closed cup
Ponto de fulgor (°C)
2.0 °C - closed cup
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Artigos
The HPLC method was first optimized using a ginsenoside standard mixture and was then applied to a sample of American Ginseng root.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica