Direkt zum Inhalt
Merck

KCQS00

Sigma-Aldrich

KiCqStart® SYBR® Green qPCR-Fertigmix

For Bio-Rad, Cepheid, Eppendorf, Illumina, Corbett, and Roche systems

Synonym(e):

qPCR master mix, sybr green qPCR

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41106300
NACRES:
NA.55

Form

liquid

Verwendung

sufficient for 1250 reactions
sufficient for 250 reactions
sufficient for 5000 reactions

Leistungsmerkmale

dNTPs included
hotstart

Lagerbedingungen

protect from light

Methode(n)

qPCR: suitable

Farbe

colorless

Aufnahme

purified DNA

Kompatibilität

for use with Bio-Rad CFX384
for use with Bio-Rad CFX96
for use with Bio-Rad MJ Chromo4
for use with Bio-Rad MJ Opticon 2
for use with Bio-Rad MJ Opticon Cepheid SmartCycler
for use with Bio-Rad MiniOpticon
for use with Bio-Rad MyiQ
for use with Eppendorf® Mastercycler ep realplex2 s
for use with Eppendorf® Mastercycler ep realplex
for use with Illumina Eco qPCR
for use with Qiagen Corbett Rotor-Gene 3000
for use with Qiagen Corbett Rotor-Gene 6000
for use with Qiagen Corbett Rotor-Gene Q
for use with Roche LightCycler 480

Nachweisverfahren

SYBR® Green

Versandbedingung

dry ice

Lagertemp.

−20°C

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

KiCqStart SYBR Green qPCR Readymix ist ein 2X-konzentrierter, gebrauchsfertiger Mastermix, der alle Komponenten, bis auf Primer und Matrize, für quantitative Echtzeit-PCR (qPCR) enthält. Diese einzigartige Kombination aus proprietären Puffern, Stabilisatoren und Hot-Start-Taq-DNA-Polymerase bietet maximale PCR-Effizienz, Sensitivität, Spezifität und ein robustes Fluoreszenzsignal unter Anwendung von schnellen oder herkömmlichen Zyklusprotokollen mit SYBR Green qPCR.

Eine hochspezifische Amplifikation ist für eine erfolgreiche qPCR mit SYBR Green I-Färbetechnologie unerlässlich, da dieser Farbstoff an alle während der Amplifikation erzeugten dsDNA-Moleküle bindet und diese nachweist. Hot-Start-Taq-DNA-Polymerase ist Antikörper-vermittelt und somit vor dem anfänglichen PCR-Denaturierungsschritt inaktiv.

Anwendung

KiCqStart® SYBR® Green qPCR ReadyMix wird verwendet, um eine quantitative Echtzeit-PCR (qPCR) für die Amplifikation und Quantifizierung von genomischer DNA aus dem humanen Darmbakterium Prevotella copri durchzuführen.
PCR-Anwendungen:
  • Genexpressionen
  • DNA-Quantifizierung
  • CHiP

Leistungsmerkmale und Vorteile

  • Assay-Ergebnisse in nur 33 Minuten
  • Hocheffiziente und empfindliche Echtzeit-PCR-Ergebnisse
  • Wenig bis keine Optimierung erforderlich

Komponenten

2X Reaktionspuffer mit optimierten Konzentrationen von MgCl2, dNTPs (dATP, dCTP, dGTP, dTTP), KiCqStart Taq-DNA-Polymerase, SYBR-Green-Farbstoff und Stabilisatoren

Verpackung:
250 Reaktionen* = 2 X 1,25-ml-Röhrchen
1250 Reaktionen* = 10 X 1,25-ml-Röhrchen
5000 Reaktionen* = 1 X 50-ml-Röhrchen
* Anzahl der Reaktionen auf Grundlage eines Volumens von 20 μl

Sonstige Hinweise

Lagerbedingungen:
KiCqStart SYBR Green qPCR-Fertigmix ist bei lichtgeschützter Lagerung in einem Gefrierschrank mit konstanter Temperatur bei -20 °C 1 Jahr lang stabil. Zur bequemeren Nutzung kann der Mix ungefroren bis zu 6 Monate bei +2 bis +8 °C aufbewahrt werden. Nach dem Auftauen die Bestandteile vor der Verwendung gründlich mischen. Wiederholtes Einfrieren und Auftauen wird nicht empfohlen. Nichtsdestotrotz zeigte das Produkt nach 20 Einfrier-/Auftauzyklen bzw. 2 Monaten Lagerung bei +20 °C keinen Leistungsverlust.
Instrumentenkompatibilität:
Verschiedene Echtzeit-PCR-Systeme nutzen verschiedene Strategien für die Normalisierung von Fluoreszenzsignalen und zur Korrektur optischer Abweichungen zwischen den Wells. Es ist entscheidend, das geeignete qPCR-Reagenz für Ihr spezifisches Instrument zu wählen. KiCqStart SYBR Green qPCR-Fertigmix enthält keinen internen Referenzfarbstoff. Kompatible Instrumente sind:
  • Bio-Rad® CFX384
  • Bio-Rad CFX96
  • Bio-Rad MiniOpticon
  • Bio-Rad/MJ Chromo4
  • Bio-Rad/MJ Opticon 2
  • Bio-Rad/MJ Opticon
  • Cepheid SmartCycler®
  • Eppendorf Mastercycler® ep realplex
  • Eppendorf Mastercycler ep realplex2 s
  • Illumina Eco qPCR
  • Qiagen/Corbett Rotor-Gene® 3000
  • Qiagen/Corbett Rotor-Gene 6000
  • Qiagen/Corbett Rotor-Gene Q
  • Roche LightCycler® 480

Rechtliche Hinweise

Bio-Rad is a registered trademark of Bio-Rad Laboratories, Inc.
CFX384 is a trademark of Bio-Rad Laboratories, Inc.
CFX96 is a trademark of Bio-Rad Laboratories, Inc.
Chromo4 is a trademark of Bio-Rad Laboratories, Inc.
Eppendorf is a registered trademark of Eppendorf AG
KiCqStart is a registered trademark of QIAGEN Beverly Inc.
LightCycler is a registered trademark of Roche
Mastercycler is a registered trademark of Eppendorf AG
MiniOpticon is a trademark of Bio-Rad Laboratories, Inc.
Opticon is a trademark of Bio-Rad Laboratories, Inc.
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
Rotor-Gene is a registered trademark of Qiagen GmbH
SYBR is a registered trademark of Life Technologies
SmartCycler is a registered trademark of Cepheid, Inc.

Lagerklassenschlüssel

12 - Non Combustible Liquids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Muthappa Senthil-Kumar et al.
Nature protocols, 9(7), 1549-1562 (2014-06-06)
Tobacco rattle virus (TRV)-based virus-induced gene silencing (VIGS) is widely used in various plant species to downregulate the expression of a target plant gene. TRV is a bipartite, positive-strand RNA virus with the TRV1 and TRV2 genomes. To induce post-transcriptional
Tsion Zewdu Minas et al.
Oncotarget, 8(21), 34141-34163 (2016-05-19)
Ewing sarcoma (ES) involves a tumor-specific chromosomal translocation that produces the EWS-FLI1 protein, which is required for the growth of ES cells both in vitro and in vivo. However, an EWS-FLI1-driven transgenic mouse model is not currently available. Here, we
YK-4-279 effectively antagonizes EWS-FLI1 induced leukemia in a transgenic mouse model.
Minas TZ
Oncotarget, 6(35), 37678-37694 (2015)
Phebe Verbrugghe et al.
BMC microbiology, 21(1), 23-23 (2021-01-13)
Since its discovery in 2007, the importance of the human gut bacterium Prevotella copri (P. copri) has been widely recognized with its links to diet and health status and potential as next generation probiotic. Therefore, precise, convenient and cost-effective diagnostic
NLRX1 Enhances Glutamate Uptake and Inhibits Glutamate Release by Astrocytes
Mahmoud S, et al.
Cells, 8(5), 400-400 (2019)

Artikel

After a traditional PCR has been completed, the PCR/qPCR data analysis is conducted by resolution through an agarose gel or, more recently, through a capillary.

Nach Abschluss einer herkömmlichen PCR erfolgt die Analyse der PCR/qPCR-Daten durch Auflösung in einem Agarosegel oder aktueller durch eine Kapillare.

PCR assay guide navigates you through primer validation and other assay optimization factors to ensure high sensitivity and specificity for optimum DNA/ RNA quantification.

Der PCR-Assay-Leitfaden führt Sie durch die Primer-Validierung und andere Faktoren der Assay-Optimierung, um eine hohe Sensitivität und Spezifität für eine optimale DNA/RNA-Quantifizierung zu gewährleisten.

Alle anzeigen

Protokolle

Quantitative PCR protocol using SYBR Green reagents. Procedure supports most qPCR instruments.

Die Analyse von Genexpressionsdaten erfordert eine stabile Referenz- oder Ladekontrolle. Diese Referenz besteht in der Regel aus einem oder mehreren Referenzgenen.

Bei der Gradienten-PCR zur Assay-Optimierung wird die optimale Hybridisierungstemperatur (Ta) der Primer bestimmt, indem identische Reaktionen mit einer feststehenden Primer-Konzentration in einem ganzen Hybridisierungstemperaturen-Bereich getestet werden.

Die Optimierung der qPCR-Bedingungen ist wichtig für die Entwicklung eines robusten Assays. Die beiden wichtigsten Ansätze sind die Optimierung der Primerkonzentration und/oder der Hybridisierungstemperaturen.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.