GE17-0727-20
SOURCE™ 15RPC
Cytiva 17-0727-20, pack of 10 mL
About This Item
Empfohlene Produkte
ligand
matrix surface
Leistungsmerkmale
autoclavable 20 min at 121°C
Verpackung
pack of 10 mL
Hersteller/Markenname
Cytiva 17-0727-20
Matrix
polystyrene/divinylbenzene
Durchschnittliche Teilgröße
15 μm (monosized)
cleaning in place
1-14
working range
1-12
Kapazität
~10 mg binding capacity
Eignung
suitable for bioprocess medium
Allgemeine Beschreibung
Anwendung
High quality assurance standards in combination with the patented production method, particle structure is consistent both bead-to-bead and batch-to-batch.
A controlled pore size distribution and large specific surface area offer excellent capacity for a wide range of molecules, from small peptides and oligonucleotides up to large Proteins. With full pH range stability, SOURCE™ 15RPC is a strong alternative to silica-based RPC matrices.
SOURCE™ 15RPC is available in a range of different bulk pack sizes for easy scale-up and process development. As member of the BioProcess media range, SOURCE™ 15RPC meets industrial demands with security of supply and comprehensive technical and regulatory support.
Leistungsmerkmale und Vorteile
- Mono-sized 15 μm rigid beads gives Low back pressures and high flow rates allowing for high productivity.
- Designed for high resolution reversed phase chromatography of Proteins, peptides and oligonucleotides.
- High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH
- BioProcess medium supported for industrial applications.
Lagerung und Haltbarkeit
Hinweis zur Analyse
Rechtliche Hinweise
Signalwort
Warning
H-Sätze
Lagerklassenschlüssel
3 - Flammable liquids
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Artikel
Poor-quality eluent components can cause a phenomenon referred to as “ghosting”. Trace levels of organic impurities bind to the medium, concentrating during equilibration and sample application. When elution begins, these contaminants appear in the chromatogram as unknown, or “ghost” peaks.
This page discusses column packing and preparation techniques for reverse phase chromatography
This page shows Hydrophobic Interaction Chromatography (HIC) in a purification strategy.
Protokolle
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.