跳轉至內容
Merck
全部照片(1)

Key Documents

P-906

Supelco

普拉西泮 溶液

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C19H17ClN2O
CAS號碼:
分子量::
324.80
EC號碼:
分類程式碼代碼:
41116107
NACRES:
NA.24

等級

certified reference material

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

Narcotic Licence Schedule B (Switzerland); psicótropo (Spain); Decreto Lei 15/93: Tabela IV (Portugal)

濃度

1.0 mg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

clinical testing

格式

single component solution

儲存溫度

2-8°C

SMILES 字串

Clc1ccc2N(CC3CC3)C(=O)CN=C(c4ccccc4)c2c1

InChI

1S/C19H17ClN2O/c20-15-8-9-17-16(10-15)19(14-4-2-1-3-5-14)21-11-18(23)22(17)12-13-6-7-13/h1-5,8-10,13H,6-7,11-12H2

InChI 密鑰

MWQCHHACWWAQLJ-UHFFFAOYSA-N

一般說明

Prazepam is a benzodiazepine prescribed for the short-term treatment of anxiety. Sold under the trade name Centrax, this drug also has anticonvulsant, sedative, and muscle relaxant effects. This Snap-N-Spike® Reference Solution is suitable for use in LC/MS or GC/MS applications for urine drug testing, clinical toxicology, or forensic analysis.

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 1

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

M Soyka et al.
Der Nervenarzt, 65(9), 628-632 (1994-09-01)
We report the case of a 61-year old patient with an affective disorder who had been treated with benzodiazepines in low dosages over a 16 year period. This treatment had been prescribed by his physician following several depressive episodes. During
X H Chen et al.
Journal of chromatography, 617(1), 147-151 (1993-07-23)
The lot-to-lot reproducibilities of Bond Elut Certify and Clean Screen DAU columns are described. The recoveries of five test drugs obtained from twelve lots of Bond Elut Certify columns ranged from 84 to 104% with standard deviations of less than
H L Tai et al.
Clinical biochemistry, 26(3), 165-171 (1993-06-01)
A simple, rapid high-pressure liquid chromatography (HPLC) method was developed for detecting and quantifying benzodiazepines in serum. Seven major benzodiazepines were extracted from spiked serum samples using solid-phase extraction with prazepam as the internal standard. The eluted drugs were then
François-Ludovic Sauvage et al.
Journal of separation science, 32(18), 3074-3083 (2009-08-22)
LC coupled to single (LC-MS) and tandem (LC-MS/MS) mass spectrometry is recognized as the most powerful analytical tools for metabolic studies in drug discovery. In this article, we describe five cases illustrating the utility of screening xenobiotic metabolites in routine
H A Archontaki et al.
Journal of pharmaceutical and biomedical analysis, 17(4-5), 739-750 (1998-07-31)
A reversed-phase HPLC method was developed for the kinetic investigation of the acidic hydrolysis of prazepam which was carried out in hydrochloric acid solutions of 0.01, 0.1 and 1.0 M. In addition, a fourth-order derivative method for monitoring the parent

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務