推薦產品
形狀
methanol solution
包裝
pkg of 1 × 1 mL (330709W-1EA)
製造商/商標名
Avanti Research™ - A Croda Brand
應用
lipidomics
metabolomics
運輸包裝
dry ice
儲存溫度
−20°C
包裝
2 mL棕色玻璃密封安瓿
成分
SPLASH LIPIDOMIX质谱标准品是1 mL甲醇溶液,含有以下成分:
混合物成分目标浓度(μM)
混合物成分目标浓度(μM)
- 15:0-18:1 (d7) PC 210
- 15:0-18:1 (d7) PE7 7
- 15:0-18:1 (d7) PS(钠盐) 10
- 15:0-18:1 (d7) PI(NH4盐) 10
- 18:1-(d7) Lyso PC 45
- 18:1-(d7) Lyso PE 1
- 18:1 (d7)胆固醇酯 530
- C18(plasm)-18:1(d9) PC 10
- 15:0-18:1-(d7) DAG 20
- 15:0-18:1-(d7):15:0 TAG 70
- d18:1-18:1-(d9) SM 40
- C18(plasm)-18:1(d9) PE 0.1
法律資訊
Avanti Research is a trademark of Avanti Polar Lipids, LLC
LIPIDOMIX is a trademark of Avanti Polar Lipids, LLC
SPLASH is a trademark of Avanti Polar Lipids, LLC
套裝中的組件也可單獨購買
產品號碼
描述
SDS
- 160μg/mL
- 791638C15:0-18:1-d7-PE, Avanti Research™ - A Croda Brand 5μg/mLSDS
- 791639C15:0-18:1-d7-PS, Avanti Research™ - A Croda Brand 8μg/mLSDS
- 791641C15:0-18:1-d7-PI, Avanti Research™ - A Croda Brand 8μg/mLSDS
- 791643C18:1-d7 Lyso PC, Avanti Research™ - A Croda Brand 25μg/mLSDS
- 791644C18:1-d7 Lyso PE, Avanti Research™ - A Croda Brand 791644C 0.5μg/mLSDS
- 700185M18:1 Chol (D7) ester, 25,26,26,26,27,27,27-heptadeuteriocholest-5-en-3β-ol (9Z-octadecenoate), methylene chloride solution 350μg/mLSDS
- 852475CC18(plasm)-18:1(d9) PC, Avanti Research™ - A Croda Brand, chloroform solution 8μg/mLSDS
- 791647C15:0-18:1-d7 DG, Avanti Research™ - A Croda Brand 791647C 12μg/mLSDS
- 791648C15:0-18:1-d7-15:0 TG, Avanti Research™ - A Croda Brand 791648C 55μg/mLSDS
- 791649C18:1-d9 SM, Avanti Research™ - A Croda Brand 30μg/mLSDS
- 852474CC18(plasm)-18:1(d9) PE, Avanti Research™ - A Croda Brand, chloroform solution 0.07μg/mLSDS
查看全部 (12)
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
標靶器官
Eyes
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 2
閃點(°F)
49.5 °F - closed cup
閃點(°C)
9.7 °C - closed cup
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
客戶也查看了
Cell, 180(1), 135-149 (2019-12-31)
Autophagy is a conserved catabolic homeostasis process central for cellular and organismal health. During autophagy, small single-membrane phagophores rapidly expand into large double-membrane autophagosomes to encapsulate diverse cargoes for degradation. It is thought that autophagic membranes are mainly derived from
Journal of lipid research, 61(1), 105-115 (2019-11-17)
Quantitative MS of human plasma lipids is a promising technology for translation into clinical applications. Current MS-based lipidomic methods rely on either direct infusion (DI) or chromatographic lipid separation methods (including reversed phase and hydrophilic interaction LC). However, the use
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務