跳轉至內容
Merck
全部照片(3)

Key Documents

185426

Sigma-Aldrich

邻甲基苯胺

≥99%

同義詞:

2-氨基甲苯, 2-甲基苯胺

登入查看組織和合約定價


About This Item

線性公式:
CH3C6H4NH2
CAS號碼:
分子量::
107.15
Beilstein:
741981
EC號碼:
MDL號碼:
分類程式碼代碼:
12352100
PubChem物質ID:
NACRES:
NA.22

蒸汽密度

3.7 (vs air)

品質等級

蒸汽壓力

0.26 mmHg ( 25 °C)

化驗

≥99%

形狀

liquid

自燃溫度

899 °F

折射率

n20/D 1.572 (lit.)

bp

199-200 °C (lit.)
89-90 °C/11 mmHg (lit.)

mp

−28 °C (lit.)

溶解度

alcohol: soluble
diethyl ether: soluble
water: slightly soluble

密度

1.008 g/mL at 25 °C (lit.)

SMILES 字串

Cc1ccccc1N

InChI

1S/C7H9N/c1-6-4-2-3-5-7(6)8/h2-5H,8H2,1H3

InChI 密鑰

RNVCVTLRINQCPJ-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

在HCl介质中,以过硫酸铵为氧化剂,邻甲苯胺与苯胺发生化学氧化聚合

應用

邻甲苯胺用于测定生物材料中的葡萄糖它被用作合成聚(邻甲苯胺)和铜纳米颗粒复合材料的前体

訊號詞

Danger

危險分類

Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Acute 1 - Aquatic Chronic 2 - Carc. 1B - Eye Irrit. 2

儲存類別代碼

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

水污染物質分類(WGK)

WGK 3

閃點(°F)

185.0 °F - closed cup

閃點(°C)

85 °C - closed cup

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

客戶也查看了

Slide 1 of 2

1 of 2

In situ synthesis of copper nanoparticles and poly (< i> o</i>-toluidine): A metal-polymer composite material.
Mallick K, et al.
Eur. Polymer J., 42(3), 670-675 (2006)
Oxidative copolymers of aniline with o-toluidine: Their structure and thermal properties.
Huang M-R, et al.
Journal of Applied Polymer Science, 81(8), 1838-1847 (2001)
A T Smit et al.
Bioresource technology, 243, 994-999 (2017-07-30)
Enzymatic cellulose hydrolysis of pretreated wheat straw pulp to glucose is enhanced when the hydrolysis is performed in the presence of an aqueous extract of the wheat straw. A relative digestibility increase of about 10% has been observed for organosolv
Hun-Je Jo et al.
Chemosphere, 70(6), 949-957 (2007-09-26)
In this study, major toxicants in pigment wastewaters (i.e. raw wastewater and effluent) were determined by toxicity identification evaluations (TIEs), and changes in their toxicities due to combined gamma-ray (gamma-ray) and ozone treatments were evaluated. From TIE results using Daphnia
Arnaldo D'Amico et al.
Lung cancer (Amsterdam, Netherlands), 68(2), 170-176 (2009-12-05)
The use of gas sensor arrays as medical diagnosis instruments has been proposed several years ago. Since then, the idea has been proven for a limited number of diseases. The case of lung cancer is particularly interesting because it is

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務