00940
Formic acid
for LC-MS LiChropur™, 97.5-98.5% (T)
About This Item
Recommended Products
vapor density
1.6 (vs air)
vapor pressure
44.8 mmHg ( 20 °C)
assay
97.5-98.5% (T)
form
liquid
autoignition temp.
1004 °F
expl. lim.
57 %
technique(s)
LC/MS: suitable
impurities
1.5-2.5% water
evapn. residue
≤0.002%
refractive index
n20/D 1.370 (lit.)
bp
100-101 °C (lit.)
mp
8.2-8.4 °C (lit.)
density
1.22 g/mL at 25 °C (lit.)
anion traces
chloride (Cl-): ≤5 mg/kg
sulfate (SO42-): ≤5 mg/kg
sulfite (SO32-): ≤10 mg/kg
cation traces
Ca: ≤1.0 mg/kg
Co: ≤0.1 mg/kg
Cr: ≤0.1 mg/kg
Cu: ≤5.0 mg/kg
Fe: ≤0.5 mg/kg
Mn: ≤0.1 mg/kg
NH4+: ≤10 mg/kg
Ni: ≤0.1 mg/kg
Pb: ≤0.1 mg/kg
Zn: ≤0.5 mg/kg
SMILES string
OC=O
InChI
1S/CH2O2/c2-1-3/h1H,(H,2,3)
InChI key
BDAGIHXWWSANSR-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
Legal Information
Related product
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 3 - Skin Corr. 1A
supp_hazards
Storage Class
3 - Flammable liquids
wgk_germany
WGK 1
flash_point_f
121.1 °F - closed cup
flash_point_c
49.5 °C - closed cup
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
A simplified LC-MS/MS method to determine glyphosate and related compounds using a Supel™ Carbon LC U/HPLC column for stability under higher pH conditions and sufficient retention for the polar analytes in the presence of methanol as an extraction solvent.
This article validates the ability to perform cleanup of urine samples using HLB solid-phase extraction (SPE) for the analysis of opioids via tandem mass spectrometry (LC-MS/MS) after cleanup with the Supel™ Swift HLB 96-well plate.
This page provides tables that list the products used in promulgated methods for Per- and polyfluoroalkyl substances (PFAS) analysis, organized by method and step for easy reference. As new methods are released, this page will be updated.
Related Content
Step-by-step reversed phase UHPLC-MS workflow for middle-up mass analysis of an immunoglobulin G antibody, consisting of antibody purification, IdeS proteolysis and reduction, mass spectrometer calibration, mAb quantification, and a system suitability test.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service