material
polyethersulfone membrane
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
Quality Level
sterility
irradiated
non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XL 300
feature
hydrophobic
manufacturer/tradename
Opticap®
parameter
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
4.1 bar max. inlet pressure (60 psi) at 23 °C
4.2 bar max. differential pressure (60 psid) at 25 °C (Forward)
60 psi max. differential pressure (4.1 bar) (continuous)
60 psig max. inlet pressure
technique(s)
gas filtration: suitable
L
11.9 cm (4.7 in.)
diam.
5.6 cm (2.2 in.)
filtration area
0.048 m2
inlet connection diam.
3/4 in.
inlet to outlet W
11.9 cm (4.7 in.)
outlet connection diam.
3/4 in.
impurities
≤0.25 EU/mL (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤3 mg
matrix
Millipore Express® SPG
pore size
0.2 μm pore size
bubble point
≥1210 mbar (17.5 psig), air with 70/30% IPA/water at 23 °C
fitting
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet sanitary flange
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)
shipped in
ambient
Looking for similar products? Visit Product Comparison Guide
General description
Packaging
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Preparation Note
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After gamma irradiation and three autoclave cycles, the TOC was measured to be equal to or less than 3367 µg/device.
Legal Information
Disclaimer
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Global Trade Item Number
SKU | GTIN |
---|---|
KEGBG003FF3 | 4053252970405 |
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service