Milli-Q

A10® TOC Monitor

suitable for water monitoring

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41104200
eCl@ss:
33050190
NACRES:
NA.21

opakowanie

pkg of 1 unit

Zastosowanie

water monitoring

Warunki transportu

ambient

Opis ogólny

A10® TOC Monitor can be used for the accurate online measurement of total organic carbon (TOC) content in ultrapure water delivered by Milli-Q® water purification systems without a built-in TOC monitor. It is compatible with any high purity water laboratory system.

Zastosowanie

A10® TOC Monitor is an ideal accessory for use in water monitoring. It is reported for use in the measurement of TOC/organic content in purified water and in water used as eluent in LC-MS studies.

Cechy i korzyści

  • High accuracy enabled by complete oxidation of organics to their end-point reaction, attributed to oxidation and conductivity measurements occurring within the same cell.
  • Range (1 – 999) and precision passing USP & EP suitability tests according to Milli-Q® Quality Assurance System standard procedures and specifications.
  • Traceability of measurement equipment is performed as per the Milli-Q® Calibration System. Certification of calibration is provided to comply with the industry requirements. A10® TOC Monitor can be recalibrated at user request and has been designed to take into account the suitability test requirements as specified in USP <643>.

Informacje prawne

A10 is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
This page may contain text that has been machine translated.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

P W M H Smeets et al.
Water research, 40(17), 3239-3248 (2006-08-30)
To determine the disinfection efficacy of ozonation, water companies can apply several disinfection calculation methods. The goal of this study was to evaluate the use of the T10 and continuous stirred tank reactor (CSTR) method to extrapolate inactivation rates of

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej