SCT260

Sigma-Aldrich

BioTracker Green Lipid Peroxide Live Cell Ferroptosis Indicator

Human

Synonim(y):

lipid peroxide live cell dye, lipid peroxide probe, live cell ferroptosis indicator

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41106514
NACRES:
NA.47

Nazwa produktu

BioTracker Green Lipid Peroxide Live Cell Ferroptosis Indicator,

pochodzenie biologiczne

human

Poziom jakości

opakowanie

vial of 250 μg

producent / nazwa handlowa

Millipore

metody

cell culture | stem cell: suitable
flow cytometry: suitable

Warunki transportu

2-8°C

temp. przechowywania

2-8°C

Opis ogólny

This perylene derivative probe containing oligooxyethylene is designed for detection of lipid peroxides. BioTracker Green Lipid Peroxide Live Cell Ferroptosis Indicator emits intense fluorescence by lipid peroxide specific oxidation in organic solvents such as ethanol. This is the only RUO probe that can specifically detect lipid peroxides.SCT260′s oxidized form is nearly nonfluorescent in an aqueous media, but produces a bright fluorescence in lipophilic sites such as in cell membranes.This probe is light-sensitive, and should be pipetted as quickly as possible, preferably within one minute. Protect working solutions and samples from light, and use within one day of preparing working solution.

Cechy i korzyści

This perylene derivative probe containing oligooxyethylene is designed for the detection of lipid peroxides in live cells.

Opis wartości docelowych

This perylene derivative containing oligooxyethylene is designed for the detection of lipid peroxides. SCT260 emits intense fluorescence by lipid peroxide-specific oxidation in organic solvents such as ethanol. Among fluorescent probes that detect Reactive Oxygen Species(ROS), SCT260 is the only compound that can specifically detect lipid peroxides. Because the excitation and emission wavelengths of the oxidized probe are 524 nm and 535 nm, respectively, phototoxicity to and autofluorescence from the sample can be minimized. The tetraethyleneglycol group linked to one end of diisoquinoline ring enhances solubility and dispersibility in aqueous buffer.

Przechowywanie i stabilność

Store BioTracker Green Lipid Peroxide Live Cell Ferroptosis Indicator at 2 - 8 °C, protected from light.

Inne uwagi

Live cell probe for fluorescent detection of lipid peroxidation by fluorescence microscopy or flow cytometry. SCT260 is a valuable reagent for ferroptosis research.

Informacje prawne

BioTracker is a trademark of Merck KGaA, Darmstadt, Germany

Oświadczenie o zrzeczeniu się odpowiedzialności

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Ta strona może zawierać tekst przetłumaczony maszynowo.

Kod klasy składowania

11 - Combustible Solids

Klasa zagrożenia wodnego (WGK)

WGK 3

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej