Millipore Express® SHR, Opticap® XLT Capsule
Opticap® XLT 30, sterile, inlet connection diam. 1.5 in., cartridge nominal length 30 in. (75 cm)
Synonim(y):
Opticap Sterile XLT 30 Millipore Express SHR single layer 0.1μm 1-1/2 in. TC/TC without gauge port
About This Item
Polecane produkty
Materiały
polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
silicone seal
Poziom jakości
zgodność regionalna
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterylność
irradiated
sterile
linia produktu
Opticap® XLT 30
Właściwości
hydrophilic
producent / nazwa handlowa
Millipore Express®
Parametry
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
metody
sterile filtration: suitable
Długość
87.2 cm (34.3 in.)
długość nominalna kartridża
30 in. (75 cm)
Średnica
10.7 cm (4.2 in.)
powierzchnia filtracyjna
2.06 m2
śr. przyłącza doprowadzającego
1.5 in.
szer. od złącza doprowadzającego do złącza odprowadzającego
15.2 cm (6.0 in.)
śr. przyłącza odprowadzającego
1.5 in.
zanieczyszczenia
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
macierz
Millipore Express® SHR
wielkość porów
0.1 μm
punkt pęcherzykowania
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
dopasowywanie
1/4 in. drain/vent hose barb (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Powiązane kategorie
Opis ogólny
Opakowanie
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Uwaga dotycząca przygotowania
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Komentarz do analizy
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 33 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informacje prawne
Nie możesz znaleźć właściwego produktu?
Wypróbuj nasz Narzędzie selektora produktów.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej