KHGLG3TTT1
Multilayer Durapore® 0.45/0.22 µm, Opticap® XLT Capsule
inlet connection diam. 1.5 in., Opticap® XLT 30, pore size 0.45/0.22 μm, cartridge nominal length 30 in. (75 cm)
Synonim(y):
Opticap Gamma Compatible Multilayer XLT30 Durapore0.45/0.22 μm 1-1/2 in. TC
About This Item
Polecane produkty
Materiały
PVDF
polyester support
polyethylene support
polypropylene
polypropylene housing
polypropylene vent cap
silicone seal
Poziom jakości
zgodność regionalna
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterylność
irradiated
non-sterile
Kompatybilność ze sterylizacją
gamma compatible
linia produktu
Opticap® XLT 30
Właściwości
gamma compatible
hydrophilic
producent / nazwa handlowa
Opticap®
Parametry
≤45.0 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. inlet pressure (15 psi) at 80 °C
1.05 bar max. differential pressure (15 psid) at 80 °C (Forward)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
metody
sterile filtration: suitable
Długość
87.1 cm (34.3 in.)
Szerokość
7.8 in.
długość nominalna kartridża
30 in. (75 cm)
Średnica
10.7 cm (4.2 in.)
powierzchnia filtracyjna
1.81 m2
śr. przyłącza doprowadzającego
1.5 in.
szer. od złącza doprowadzającego do złącza odprowadzającego
15.2 cm (6.0 in.)
śr. przyłącza odprowadzającego
1.5 in.
zanieczyszczenia
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
macierz
Multilayer Durapore®
pore size
0.45/0.22 μm pore size
moc wejściowa
sample type liquid
punkt pęcherzykowania
≥3450 mbar (50 psig), air with water at 23 °C
dopasowywanie
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet sanitary flange
outlet sanitary flange
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów
Opis ogólny
Opakowanie
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Uwaga dotycząca przygotowania
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Komentarz do analizy
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 ºC.
Informacje prawne
Nie możesz znaleźć właściwego produktu?
Wypróbuj nasz Narzędzie selektora produktów.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej