Millipore Express® SHC 0.5/0.2µm, Opticap® XL 5 Capsule
Fittings 1-1/2 in. TC- 1 in. HB, Sterile
About This Item
Polecane produkty
Nazwa produktu
Millipore Express® SHC, Opticap® XL Capsule, Opticap® XL 5, sterile, cartridge nominal length 5 in. (12.5 cm), filter diam. 10.7 cm (4.2 in.)
Materiały
polyester support
polypropylene device
polypropylene housing
polypropylene vent cap
polysulfone device
silicone seal
Poziom jakości
zgodność regionalna
meets FDA 21 CFR 177-182 (all component materials)
sterylność
irradiated
sterile
linia produktu
Opticap® XL 5
Właściwości
hydrophilic
producent / nazwa handlowa
Millipore Express®
Parametry
≤14.0 mL/min air diffusion at 2.8 bar (40 psig) (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
metody
sterile filtration: suitable
długość nominalna kartridża
5 in. (12.5 cm)
Dł. urządzenia
21.6 cm (8.5 in.)
Rozmiar urządzenia
5 in.
śr. filtra
10.7 cm (4.2 in.)
Powierzchnia filtracyjna filtra
0.24 m2
zanieczyszczenia
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
Matryca
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
punkt pęcherzykowania
≥4000 mbar (58 psig), air with water
dopasowywanie
(38 mm (1 ½ in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów
Opis ogólny
Opakowanie
Uwaga dotycząca przygotowania
3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable
Komentarz do analizy
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Informacje prawne
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej