Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Key Documents

5A10HH1

Millipore

Opticap® XL10 Polygard® CR

inlet connection diam. 9/16 in., pore size 25.0 μm, cartridge nominal length 10 in. (25 cm)

Synonim(y):

Opticap® XL10 Polygard®-CR 25 µm 9/16 in. HB/HB

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
23151806
eCl@ss:
32031690

Materiały

polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal

Poziom jakości

zgodność regionalna

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

producent / nazwa handlowa

Opticap®

Parametry

1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.8 bar max. differential pressure (70 psid) at 20 °C
5.5 bar max. inlet pressure (80 psi) at 25 °C
80 psig max. inlet pressure

Długość

33.5 cm (13.2 in.)

długość nominalna kartridża

10 in. (25 cm)

Średnica

10.7 cm (4.2 in.)

śr. przyłącza doprowadzającego

9/16 in.

szer. od złącza doprowadzającego do złącza odprowadzającego

33.5 cm (13.2 in.)

śr. przyłącza odprowadzającego

9/16 in.

zanieczyszczenia

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

substancje ekstrahujące się grawimetrycznie

≤55 mg/capsule

macierz

Polygard®-CR

wielkość porów

25.0 μm nominal pore size
25.0 μm pore size

moc wejściowa

sample type liquid

dopasowywanie

inlet hose barb
14 mm (9/16 in.) inlet/outlet hose barb
outlet hose barb

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Device Configuration: Capsule

Cechy i korzyści

Format: Single Layer

Opakowanie

Double Easy-Open bag

Inne uwagi

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Powiązanie

Replaces: KR2501HB1

Uwaga dotycząca przygotowania

Sterilization Method
3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable

Komentarz do analizy

Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L

Informacje prawne

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

Oświadczenie o zrzeczeniu się odpowiedzialności

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
This page may contain text that has been machine translated.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej