1.50436

Supelco

SeQuant ZIC®-HILIC 200Å (5 µm) HPLC Columns

L × I.D. 20 mm x 2.1 mm, Guard Kit with holder and Guard Column

Synonim(y):

Hydrophilic Interaction Liquid Chromatography Guard Column

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41115709

product name

SeQuant ZIC-HILIC Guard Kit 20 x 2.1 mm, PEEK-lined stainless steel column, pkg of 3 column

Materiały

PEEK-lined stainless steel column

Poziom jakości

agency

suitable for USP L114

linia produktu

SeQuant

Właściwości

endcapped: no

opakowanie

pkg of 3 column

Parametry

550 bar pressure
70 °C max. temp.

metody

LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)

kolumna dł. × śr. wewn.

2 cm × 2.1 mm

macierz

fully porous particle

grupa aktywna macierzy

ZIC-HILIC bonding phase

wielkość cząstki

5 μm

wielkość porów

200 Å pore size

pH robocze

2-7.5

metoda separacji

hydrophilic interaction (HILIC)

temp. przechowywania

no temp limit

Opis ogólny

The SeQuant ZIC®-HILIC Guard column protects your analytical column from contamination. The guard column kit contains 3 Guard columns including the coupler.
SeQuant ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility.
The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.
Thanks to their favorable retention and robust performance, SeQuant HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant ZIC®-HILIC for analysis of melamine and related substances.
SeQuant HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.
Learn more about the Supelco HPLC Column portfolio and Method development:
Brochure: HPLC and UHPLC Column Selection Guide
Brochure: A Practical Guide to HPLC - Method Development Guide

Informacje prawne

SeQuant is a trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany
This page may contain text that has been machine translated.

Kod klasy składowania

11 - Combustible Solids


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Klienci oglądali również te produkty

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej