10836

Sigma-Aldrich

Silicone oil AR 20

viscosity ~20 mPa.s,   neat(25 °C)

Synonim(y):

Polyphenyl-methylsiloxane

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Numer CAS:
Numer MDL:
Kod UNSPSC:
12352103
NACRES:
NA.22

współczynnik refrakcji

n20/D 1.441-1.445

lepkość

~20 mPa.s, neat(25 °C)

gęstość

1.000-1.020 g/mL at 20 °C

Opis ogólny

Silicone oil AR 20 is a polydimethylsiloxane with phenyl groups that is commonly used as a heat transfer or pressure transfer fluid.

Zastosowanie

Silicone oil AR 20 has been used:
  • As a Segmenting fluid in polymerase chain reaction (PCR).
  • In hollow fiber liquid-phase microextraction (LPME) procedure for extraction of hydrophobic drugs from human breast milk.
  • As a fluid to demonstrate pores in droplet interface bilayers (DIBs).

Cechy i korzyści

Especially good thermostability (-50°C to +230°C)
Ta strona może zawierać tekst przetłumaczony maszynowo.

Kod klasy składowania

10 - Combustible liquids

Klasa zagrożenia wodnego (WGK)

WGK 3

Temperatura zapłonu (°F)

338.0 °F - Not applicable

Temperatura zapłonu (°C)

170 °C - Not applicable

Środki ochrony indywidualnej

Eyeshields, Gloves


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Klienci oglądali również te produkty

Slide 1 of 5

1 of 5

Liquid-phase microextraction of drugs from human breast milk
Bj?rhovde, A, et al.
Analytica Chimica Acta, 491(2), 155-161 (2003)
Formation of droplet interface bilayers in a Teflon tube
Walsh E, et al.
Scientific reports, 6(2), 34355-34355 (2016)
E J Walsh et al.
Biomedical microdevices, 7(4), 269-272 (2006-01-13)
This paper evaluates the compatibility of segmenting fluids for two phase flow applications in biomedical microdevices. The evaluated fluids are chosen due to the variations in fluid properties and cost, while also reflecting their use in the recent literature. These
Helena L E Coker et al.
Biophysical journal, 116(6), 1085-1094 (2019-03-09)
Diffusion in cell membranes is not just simple two-dimensional Brownian motion but typically depends on the timescale of the observation. The physical origins of this anomalous subdiffusion are unresolved, and model systems capable of quantitative and reproducible control of membrane
Gema Flores et al.
Journal of chromatography. A, 1153(1-2), 29-35 (2007-02-20)
A method based on the use of absorbents as packing materials in the interface of the direct coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) is proposed. To that end, a comparative study on different adsorbents and absorbents

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej