추천 제품
material
fused silica
Agency
meets requirements for USP G3
파라미터
0-250 °C temperature (isothermal or programmed)
베타 값
313
df
0.20 μm
기술
gas chromatography (GC): suitable
길이 × I.D.
30 m × 0.25 mm
기질 활성군
Non-bonded; poly(50% phenyl/50% methyl siloxane) phase
컬럼 유형
capillary intermediate polar
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Application: The SP-2250 column is a non-bonded 50% phenyl polymer. It is highly effective for the analysis of polar compounds.
USP Code: This column meets USP G3 requirements.
Phase:
USP Code: This column meets USP G3 requirements.
Phase:
- Non-bonded
- Poly(50% phenyl/50% methyl siloxane)
- 0 °C to 250 °C (isothermal or programmed)
애플리케이션
Capillary column coated with SP®-2250 (methyl silicone-phenyl silicone, 1:1) stationary phase may be used in gas chromatographic analysis of azaarenes (benzacridines and dibenzacridines).
기타 정보
We offer a variety of chromatography accessories including analytical syringes
법적 정보
SP is a registered trademark of Sigma-Aldrich Co. LLC
Journal - Association of Official Analytical Chemists, 70(6), 1056-1058 (1987-11-01)
An isothermal gas chromatographic method for measuring alachlor in Micro-Tech (microencapsulated) formulations was tested by 5 collaborators. The samples were prepared in acetone, and alachlor was determined using a gas chromatographic column of 10% SP-2250 on 100-120 mesh Supelcoport. Di-n-pentylphthalate
Anesthesiology, 55(2), 176-179 (1981-08-01)
Plasma midazolam concentrations following single therapeutic doses can be quantitated using electron-capture gas-liquid chromatography. After addition of a benzodiazepine analogue as an internal standard, samples are extracted with benzeneisoamyl alcohol (98.5:1.5). The organic extract is evaporated to dryness, reconstituted, and
Clinical chemistry, 25(7), 1296-1300 (1979-07-01)
We describe the use of electron-capture gas chromatography or reversed-phase "high-performance" liquid chromatography for concurrent analysis for diazepam and nordiazepam in serum. In the gas-chromatographic analysis our use of a new chemically deactivated stationary liquid phase, SP 2250-DB (Supelco, Inc.)
Journal of analytical toxicology, 6(6), 321-323 (1982-11-01)
The gas chromatographic identification of barbiturates isolated from biological material is not optimal, and due to their polar nature, it is difficult to obtain good resolution on most columns. To improve resolution, flash alkylation appeared to be a reasonable alternative.
British journal of sports medicine, 10(3), 143-146 (1976-10-01)
At the request of the Service des Haras, our laboratory works on the toxicological problems of the sport-horse. These studies have resulted in the setting up of an anti-doping control for equestrian competitions of various types, not only flat racing.