Key Documents

GE28-9924-73

HiScreen Capto Butyl

Cytiva 28-9924-73, pack of 1 column

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151817
NACRES:
NA.56

ligand

butyl

포장

pack of 1 column

제조업체/상표

Cytiva 28-9924-73

베드 크기

7.7 mm × 100 mm

컬럼 I.D.

7.7 mm

기질

highly cross-linked agarose

평균 부품 크기

75 μm (d50v)

cleaning

3-14

working range

3-13

용량

27 mg binding capacity(27 mg BSA /ml (at QB10%))

적합성

suitable for bioprocess medium

일반 설명

Capto Phenyl (High sub) and Capto Butyl are hydrophobic interaction chromatography (HIC) media used in the capture and intermediate stages of protein purification.

애플리케이션

HiScreen columns are part of the process development platform available from Cytiva. The columns are prepacked with a range of BioProcess chromatography media (resins) and designed for method optimization and parameter screening. HiScreen columns have small bed volumes (4.7 ml), reducing the cost of sample and buffer consumption. The media used in HiScreen columns are also available in other prepacked formats and as bulk packs, for all scales of work from development and pilot studies to routine production.

Capto Butyl is intended for initial and intermediate step purifications requiring a chromatography medium with Low to medium hydrophobicity. Capto Butyl often works efficiently with rather Low salt concentrations. The mechanism of binding and elution onto the butyl ligand is different from that onto the phenyl ligand, giving a different selectivity. Performance during sample run and selectivity are similar to that of Butyl Sepharose 4 Fast Flow. Higher flow rates can be used with Capto Butyl during equilibration, wash and regeneration.

특징 및 장점

  • Prepacked with Capto Butyl
  • Excellent for method optimization and parameter screening due to the 10 cm bed height
  • Easily connected in series to achieve 20 cm bed height
  • Small bed volume for fast results and minimal sample/buffer consumption
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same flow velocity

저장 및 안정성

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol)

분석 메모

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

법적 정보

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva
Sepharose is a trademark of Cytiva

픽토그램

Flame

신호어

Warning

유해 및 위험 성명서

Storage Class Code

3 - Flammable liquids


시험 성적서(COA)