콘텐츠로 건너뛰기
Merck
모든 사진(2)

Key Documents

GE11-0013-02

HiTrap® Capto Q

Cytiva 11-0013-02, pack of 5 × 1 mL

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151816
NACRES:
NA.56

ligand

quaternary amine

설명

Ion Exchanger Type (value)

포장

pack of 5 × 1 mL

제조업체/상표

Cytiva 11-0013-02

파라미터

flow rate
<4 mL/min flow rate
42 psi

베드 크기

7 mm × 25 mm

베드 용적

1 mL

컬럼 I.D.

7 mm

기질

highly cross-linked agarose with dextran surface extender

평균 직경

90 μm (d50v)

cleaning

2-14

working range

2-12

적합성

suitable for bioprocess medium

일반 설명

HiTrap® Capto Q is a strong anion exchanger prepacked with BioProcess Capto media for screening, and small-scale protein purifications using ion exchange chromatography (IEX).

애플리케이션

Capto Q has a strong quaternary ammonium (Q) anion exchanger coupled to a chemically modified, high-fLow Agarose matrix. The modified Agarose matrix provides greater particle rigidity without compromising pore size, which allows more flexibility in process-scale applications. High dynamic binding capacity is achieved with a Dextran surface extender that coats the Agarose matrix.

특징 및 장점

  • High-throughput medium for capture and intermediate purification, excellent choice for process-scale purification.
  • The combined properties of high binding capacity, high flow rate, and Low back pressure reduces process cycle times and improves productivity at process scale.
  • Rigid Agarose matrix enables high bed heights and purification of viscous samples at high flow rates.
  • Strong quaternary ammonium (Q) anion exchanger.

저장 및 안정성

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol)

분석 메모

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

기타 정보

1)The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

법적 정보

Capto is a trademark of Cytiva
HiTrap is a registered trademark of Cytiva

픽토그램

Flame

신호어

Warning

유해 및 위험 성명서

Storage Class Code

3 - Flammable liquids


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.