추천 제품
Grade
BioPerformance Certified
분석
≥99.0%
양식
crystalline
기술
cell culture | mammalian: suitable
불순물
endotoxin and bioburden, tested
pH
2.5-5.0 (25 °C, 213.3 g/L)
유용한 pH 범위
6.4-7.8
pKa(25 °C)
7.1
solubility
water: 0.5 g/mL, clear, colorless
응용 분야
diagnostic assay manufacturing
외래 활성
DNAse (exonuclease), NICKase (endonuclease), RNAse, and protease, none detected
저장 온도
room temp
SMILES string
OCCN(CCO)CCS(O)(=O)=O
InChI
1S/C6H15NO5S/c8-4-1-7(2-5-9)3-6-13(10,11)12/h8-9H,1-6H2,(H,10,11,12)
InChI key
AJTVSSFTXWNIRG-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
N-N-bis(2-hydroxyethyl)-2-aminoethanesulfonic acid (BES) is a zwitterionic sodium sulphate buffer used in biochemistry and molecular biology research. BES buffer used as a secondary pH standard can help maintain a stable pH range in solutions, particularly in the range of 6.2-7.6 pH range of 6.6 to 7.4. It is used in a study to evaluate that buffers minimize the action of interfering factors in the bacterial endotoxins test. The application of BES as a buffer solution for calcium phosphate-mediated transfection of eukaryotic cells with plasmid DNA has also been studied.
애플리케이션
BES buffer has been used:
- as a supplement in opti-minimal essential medium (MEM) culture media to culture thymocytes for In vitro analysis of thymocyte apoptosis
- as a component of borate buffer saline (BBS) for adeno-associated virus (AAV) vector production, extraction, and purification
- as a component of diluent one for semen collection and cryopreservation
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
이미 열람한 고객
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 10(12), 1449-1455 (2014-11-26)
Stent fracture is important because it may cause adverse events. The interventional cardiologist needs independent data to aid stent selection. Stent designers need data to improve stent design. We used a repetitive bend test to compare durability and fracture for
Circulation journal : official journal of the Japanese Circulation Society, 79(6), 1323-1331 (2015-04-07)
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation
The journal of physical chemistry letters, 6(15), 2933-2937 (2015-08-13)
Colloidal CdSe quantum dot (QD) core ensembles were photodimmed and allowed to recover in the dark using ambient thermal energy at a range of temperatures. Nonlinear thermal recovery is well described by a stretched exponential function, and further analysis yields
Nano letters, 15(7), 4657-4663 (2015-06-24)
Noncrystalline semiconductor materials often exhibit hysteresis in charge transport measurements whose mechanism is largely unknown. Here we study the dynamics of charge injection and transport in PbS quantum dot (QD) monolayers in a field effect transistor (FET). Using Kelvin probe
International journal of cardiology, 186, 178-185 (2015-04-02)
Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. Patients recruited in the Comfortable AMI-IBIS 4 study
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.