추천 제품
Grade
certified reference material
Quality Level
형태
liquid
포장
pkg of 5 x 1 mL
제조업체/상표
NIST®
기술
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
mass spectrometry (MS): suitable
응용 분야
clinical research
형식
matrix material
일반 설명
SRM 1950 is designed to represent “normal” human plasma.
It was developed in a collaboration between the National Institute of Standards and Technology (NIST) and the National Institutes of Health (NIH) National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK). Analyses for value assignment were performed by NIST and the Centers for Disease Control and Prevention (CDC) (Atlanta, GA). All certified and reference values, with the exception of vitamin D-binding protein, are based on the agreement between the results from NIST methods and from the CDC, where available. The reference value for vitamin D-binding protein is based on the agreement between the results from a NIST method and the University of Washington method.
SRM 1950 _SDS
SRM 1950_CERT
It was developed in a collaboration between the National Institute of Standards and Technology (NIST) and the National Institutes of Health (NIH) National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK). Analyses for value assignment were performed by NIST and the Centers for Disease Control and Prevention (CDC) (Atlanta, GA). All certified and reference values, with the exception of vitamin D-binding protein, are based on the agreement between the results from NIST methods and from the CDC, where available. The reference value for vitamin D-binding protein is based on the agreement between the results from a NIST method and the University of Washington method.
SRM 1950 _SDS
SRM 1950_CERT
애플리케이션
This Standard Reference Material (SRM) is intended primarily for the validation of methods for determining metabolites such as fatty acids, electrolytes, vitamins, hormones, and amino acids in human plasma and similar materials. This SRM can also be used for comparison of measurement technologies used in metabolomic studies and for quality assurance when assigning values to in-house reference materials.
The standard has been used:
The standard has been used:
- to determine the accuracy of vitamin D in human serum by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- to determine the unbound free fatty acid profile of human plasma
- to determine the C24 bile acids in human serum and urine samples by liquid chromatography-mass spectrometry (LC-MS) method
특징 및 장점
- A unit of SRM 1950 consists of five vials, each containing approximately 1.0 mL of plasma
- The associated uncertainties are expressed at the 95 %level of confidence
- Information on product description, disposal, and transportation is available in the accompanying MSDS
- The enclosed NIST certificate contains details on the expiry date, warning to users, instructions for right storage and use, preparation, and analysis of the RM
법적 정보
NIST is a registered trademark of National Institute of Standards and Technology
SRM is a registered trademark of National Institute of Standards and Technology
관련 제품
제품 번호
설명
가격
Storage Class Code
13 - Non Combustible Solids
WGK
WGK 3
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
Unbound free fatty acid profiles in human plasma and the unexpected absence of unbound palmitoleate
Journal of Lipid Research, 58(3), 578-585 (2017)
Quantification of vitamin D and 25-hydroxyvitamin D in soft tissues by liquid chromatography-tandem mass spectrometry
Journal of Chromatography. B, Biomedical Sciences and Applications, 932, 6-11 (2013)
Analysis of human C24 bile acids metabolome in serum and urine based on enzyme digestion of conjugated bile acids and LC-MS determination of unconjugated bile acids
Analytical and Bioanalytical Chemistry, 410(21), 5287-5300 (2018)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.