F9252

Sigma-Aldrich

Folin & Ciocalteu′s phenol reagent

suitable for determination of total protein by Lowry method, 1.9-2.1 N

로그인조직 및 계약 가격 보기


About This Item

MDL number:
UNSPSC 코드:
12171500
NACRES:
NA.47

양식

liquid

Quality Level

농도

1.9-2.1 N

색상

clear yellow
faint yellow to very dark yellow, and Faint Green-Yellow to Very Dark Green-Yellow

pH

<0.5 (20 °C)

density

1.240 g/cm3 at 20 °C

적합성

suitable for determination of total protein by Lowry method

응용 분야

diagnostic assay manufacturing
hematology
histology

저장 온도

room temp

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Folin & Ciocalteu′s phenol reagent is most commonly used in the Lowry method for determining protein concentration. It has also been used for the quantification of total phenolics. In this method, protein is pretreated with copper(II) in a modified biuret reagent (alkaline copper solution
stabilized with sodium potassium tartrate). Addition of the phenol reagent generates chromogens that give increasing absorbance between 550-750nm. Normally, absorbance at the peak (750nm) or shoulder (660nm) are used to quantitate protein concentrations between 1-100 mg/ml while absorbance at 550nm is used to quantitate higher protein concentrations.
In the absence of copper, color intensity is determined primarily by the tyrosine and tryptophan content of the protein, and to a lesser extent by cysteine and histidine. Copper(II) has no effect on color formation by tyrosine, tryptophan, or histidine, but reduces color formation due to cysteine.
Many modifications of the original assay procedure have been published, including methods for enhancing the color development, for determining the content of insoluble proteins, and for automating the procedure. Compounds including many buffers, chelating agents, detergents, and cyclic organic compounds can interfere with the Lowry protein assay.
Folin & Ciocalteu′s phenol reagent can also be used as a spray reagent in chromatographic procedures.

애플리케이션

Folin & Ciocalteu′s phenol reagent has been used for the estimation of total phenolic content in samples.

기타 정보

Folin & Ciocalteu′s phenol reagent does not contain phenol. Rather, the reagent will react with phenols and non-phenolic reducing substances to form chromogens that can be detected spectrophotometrically.

결합

This product is also available as part of a kit.

픽토그램

Corrosion

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1

Storage Class Code

8B - Non-combustible corrosive hazardous materials

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Estimation of total phenolic content and other oxidation substrates in plant tissues using Folin-Ciocalteu reagent.
Ainsworth EA and Gillespie KM
Nature Protocols, 2, 875-875 (2007)
David L Jones et al.
PloS one, 9(3), e90882-e90882 (2014-03-19)
Monitoring the properties of dissolved organic carbon (DOC) in soil water is frequently used to evaluate changes in soil quality and to explain shifts in freshwater ecosystem functioning. Using >700 individual soils (0-15 cm) collected from a 209,331 km(2) area
Han-Shin Kim et al.
Scientific reports, 6, 25318-25318 (2016-05-05)
Biofilm formation on biotic or abiotic surfaces has unwanted consequences in medical, clinical, and industrial settings. Treatments with antibiotics or biocides are often ineffective in eradicating biofilms. Promising alternatives to conventional agents are biofilm-inhibiting compounds regulating biofilm development without toxicity
Nutritional evaluation of some subtropical red and green seaweeds Part II. In vitro protein digestibility and amino acid profiles of protein concentrates.
Wong KH and Cheung PCK
Food Chemistry, 72, 11-17 (2001)
Lowry's method of protein estimation: some more insights.
S Sengupta et al.
The Journal of pharmacy and pharmacology, 45(1), 80-80 (1993-01-01)

문서

Proteinase K (EC 3.4.21.64) activity can be measured spectrophotometrically using hemoglobin as the substrate. Proteinase K hydrolyzes hemoglobin denatured with urea, and liberates Folin-postive amino acids and peptides. One unit will hydrolyze hemoglobin to produce color equivalent to 1.0 μmol of tyrosine per minute at pH 7.5 at 37 °C (color by Folin & Ciocalteu's Phenol Reagent).

프로토콜

To standardize a procedure for the determination of protein by modified Lowry.

Proteinase K (EC 3.4.21.64) activity can be measured spectrophotometrically using hemoglobin as the substrate. Proteinase K hydrolyzes hemoglobin denatured with urea, and liberates Folin-postive amino acids and peptides. One unit will hydrolyze hemoglobin to produce color equivalent to 1.0 μmol of tyrosine per minute at pH 7.5 at 37 °C (color by Folin & Ciocalteu's Phenol Reagent).

관련 콘텐츠

A wide variety of products for traditional protein quantitation techniques such as BCA and Bradford. Also, products for alternative assays such as Lowry, Micro Pyrogallol and FluoroProfile are also available for total protein determination.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.