추천 제품
Grade
ACS reagent
Quality Level
grade
puriss. p.a.
분석
≥99.0% (TLC)
양식
solid
품질
for the detection of Ni
기술
UV/Vis spectroscopy: suitable
불순물
≤0.02% insoluble matter in ethanol
무기 잔류물
≤0.05% (as SO4)
mp
240-241 °C (lit.)
solubility
water: soluble 0.1 g/10 mL, clear, colorless
양이온 미량물
Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤50 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Na: ≤50 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Zn: ≤5 mg/kg
작용기
amine
oxime
SMILES string
CC(=N/O)\C(C)=N\O
InChI
1S/C4H8N2O2/c1-3(5-7)4(2)6-8/h7-8H,1-2H3/b5-3+,6-4+
InChI key
JGUQDUKBUKFFRO-GGWOSOGESA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Dimethylglyoxime (DMG) is a complexing ligand. Dimethylglyoxime forms a number of mixed ligand complexes with N-acetylglycine with metals such as VO(IV), Ni(II), Zn(II), Pd(II), Cd(II) and Pb(II). It is a useful reagent for the spectrophotometric determination of Co(II), Fe(II), Ni(II), Pd(II) and Re(VII).
애플리케이션
Dimethylglyoxime (DMG) was used as complexing agent for cobalt(II) and nickel(II) metals for the analysis of brine for trace metals by adsorptive stripping voltammetry. DMG was used in a study to develop a new DMG containing modified sol-gel carbon composite electrode for voltammetric sensing of heavy metals.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Flam. Sol. 2
Storage Class Code
4.1B - Flammable solid hazardous materials
WGK
WGK 3
개인 보호 장비
Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
Preparation and Spectral Properties of Mixed-Ligand Complexes of VO (IV), Ni (II), Zn (II), Pd (II), Cd (II) and Pb (II) with Dimethylglyoxime and N-Acetylglycine.
Journal of Chemistry, 7(S1), S580-S586 (2010)
Dimethylglyoxime doped sol-gel carbon composite voltammetric sensor for trace nickel.
Electroanalysis, 9(9), 689-692 (1997)
Application of adsorptive stripping voltammetry (AdSV) for the analysis of trace metals in brine.
Fresenius Journal of Analytical Chemistry, 340(6), 363-370 (1991)
The Science of the total environment, 409(22), 4663-4666 (2011-09-06)
Nickel and cobalt allergy remain frequent in dermatitis patients. It is important to determine possible nickel and cobalt exposures at work as these may offer important information to regulators and physicians who perform patch testing. Clinical relevance of metal exposure
Contact dermatitis, 62(5), 279-288 (2010-06-12)
The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine-tuned to estimate
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..