추천 제품
Grade
analytical standard
Quality Level
제품 라인
VETRANAL®
유통기한
limited shelf life, expiry date on the label
농도
100 μg/mL in acetonitrile
기술
HPLC: suitable
gas chromatography (GC): suitable
응용 분야
pharmaceutical (small molecule)
형식
single component solution
저장 온도
2-8°C
SMILES string
NC(=O)N\N=C\c1ccc(o1)[N+]([O-])=O
InChI
1S/C6H6N4O4/c7-6(11)9-8-3-4-1-2-5(14-4)10(12)13/h1-3H,(H3,7,9,11)/b8-3+
InChI key
IAIWVQXQOWNYOU-FPYGCLRLSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
법적 정보
VETRANAL is a registered trademark of Merck KGaA, Darmstadt, Germany
적합한 제품을 찾을 수 없으신가요?
당사의 제품 선택기 도구.을(를) 시도해 보세요.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
35.6 °F - closed cup
Flash Point (°C)
2 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
The Journal of urology, 184(6), 2572-2577 (2010-10-30)
We determined the activity, comparative potency and effect durability of commercially available, antimicrobial coated Foley catheters against Escherichia coli isolates, including extended spectrum cephalosporin resistant strains. We used an inhibition zone assay (diffusible inhibition) and an adherence assay (diffusible and
Scientific reports, 1, 63-63 (2012-02-23)
Azoreductases are well known for azo pro-drug activation by gut flora. We show that azoreductases have a wider role in drug metabolism than previously thought as they can also reduce and hence activate nitrofurazone. Nitrofurazone, a nitroaromatic drug, is a
Lancet (London, England), 380(9857), 1927-1935 (2012-11-09)
Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital. We aimed to establish whether short-term routine use of antimicrobial catheters reduced risk of CAUTI compared with standard polytetrafluoroethylene (PTFE) catheterisation. In our parallel
Health technology assessment (Winchester, England), 16(47), 1-197 (2012-12-04)
Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital and incurs significant costs for health-care providers such as the UK NHS. Many preventative strategies and measures have been introduced to minimise CAUTI risk
Biosensors & bioelectronics, 38(1), 245-251 (2012-06-22)
Electrochemical behavior of nitrofurazone (NFZ) was investigated with the use of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. The pH-dependence of NFZ was studied at a glassy carbon electrode (GCE) in ethanol/Britton-Robinson buffer (30:70), and short-lived nitro-radicals were
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.