추천 제품
Grade
analytical standard
Quality Level
vapor density
7.7 (vs air)
vapor pressure
<0.01 mmHg ( 20 °C)
분석
≥99.7% (GC)
autoignition temp.
510 °F
유통기한
limited shelf life, expiry date on the label
range of application measuring range
≤60 °C
refractive index
n20/D 1.432 (lit.)
n20/D 1.432
bp
275-276 °C (lit.)
mp
−30 °C (lit.)
density
1.009 g/mL at 25 °C (lit.)
응용 분야
environmental
형식
neat
SMILES string
COCCOCCOCCOCCOC
InChI
1S/C10H22O5/c1-11-3-5-13-7-9-15-10-8-14-6-4-12-2/h3-10H2,1-2H3
InChI key
ZUHZGEOKBKGPSW-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Tetraethylene glycol dimethyl ether is a non-volatile, higher molecular weight glyme solvent.
애플리케이션
Tetraethylene glycol dimethyl ether may be used as an analytical reference standard for the quantification of the analyte in water samples using gas chromatography/mass spectrometry technique.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Repr. 1B
보충제 위험성
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGK
WGK 1
Flash Point (°F)
276.8 °F - closed cup
Flash Point (°C)
136 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Complement activation on poly(ethylene oxide)-like radiofrequency glow discharge-deposited surfaces.
Journal of biomedical materials research. Part A, 96(1), 150-161 (2010-11-26)
Nonspecific protein adsorption, particularly fibrinogen (Fg), is thought to be an initiating step in the foreign body response (FBR) to biomaterials by promoting phagocyte attachment. In previous studies, we therefore prepared radiofrequency glow discharge (ethylene oxide)-like tetraglyme (CH(3)O(CH(2)CH(2)O)(4)CH(3)) coatings adsorbing
Langmuir : the ACS journal of surfaces and colloids, 26(5), 3720-3730 (2009-12-03)
Physical and photolithographic techniques are commonly used to create chemical patterns for a range of technologies including cell culture studies, bioarrays and other biomedical applications. In this paper, we describe the fabrication of chemical micropatterns from commonly used plasma polymers.
Journal of biomedical materials research. Part A, 89(3), 791-803 (2008-05-23)
Previous studies have showed that radio-frequency plasma deposited tetraglyme coatings greatly reduced fibrinogen adsorption (Gamma(Fg)) from highly diluted plasmas (0.1 and 1%) and subsequent platelet adhesion under static conditions. In this study, the protein resistant properties of tetraglyme were re-examined
Journal of the American Chemical Society, 131(15), 5530-5539 (2009-03-28)
Poly(ethylene) oxide (PEO) is a technologically important polymer with a wide range of applications including ion-exchange membranes, protein crystallization, and medical devices. PEO's versatility arises from its special interactions with water. Water molecules may form hydrogen-bond bridges between the ether
Journal of chromatography. A, 922(1-2), 207-218 (2001-08-07)
A recently developed method for the sampling and analysis of volatile organic compounds in air has been evaluated. The system is based on the enrichment of analytes in tetraethylene glycol dimethyl ether or tetraglyme, a water-soluble organic liquid. The subsequent
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.