EHIFI-RO

Roche

Expand High Fidelity PCR System

sufficient for ≤40 reactions (11732641001), sufficient for ≤200 reactions (11732650001), sufficient for ≤1,000 reactions (11759078001)

동의어(들):

high fidelity pcr system, expand

로그인조직 및 계약 가격 보기


About This Item

효소 위원회 번호:
UNSPSC 코드:
41106300

사용

sufficient for ≤1,000 reactions (11759078001)
sufficient for ≤200 reactions (11732650001)
sufficient for ≤40 reactions (11732641001)

Quality Level

포장

pkg of 2,500 U (11759078001 [10x250 U])
pkg of 100 U (11732641001)
pkg of 500 U (11732650001 [2x250 U])

제조업체/상표

Roche

기술

PCR: suitable

저장 온도

−20°C

일반 설명

Expand High Fidelity PCR System is optimized to efficiently amplify DNA fragments up to 5 kb. PCR up to 9 kb is possible, with yield diminishing as DNA fragment length increases. The Expand High Fidelity PCR System is composed of an enzyme mix containing thermostable Taq DNA polymerase and a thermostable DNA polymerase with proofreading activity. The fidelity of DNA synthesis with Expand High Fidelity PCR System shows a threefold increase compared to Taq DNA polymerase. T/A cloning is recommended.
The 5′ → 3′ polymerase activity of Taq DNA Polymerase and the 3′ → 5′ exonuclease of the proofreading polymerase combine for improved performance and results; 3′ → 5′ exonuclease proofreading produces a threefold increase in DNA synthesis fidelity compared to Taq DNA polymerase.

애플리케이션

The Expand High Fidelity PCR System is an enzyme blend delivering superior results with twofold higher yield and threefold greater fidelity compared to Taq DNA Polymerase. Choose Expand High Fidelity PCR System for the most sensitive PCR results for genomic targets up to 5 kb in length in:
  • PCR
  • RT-PCR

Use Expand High Fidelity PCR System, dNTPack with ready-to-use PCR nucleotide mix.
For maximum convenience, select the 2x concentrated ready-to-use High Fidelity Master.

특징 및 장점

Expand High Fidelity PCR System is a mixture of Taq DNA polymerase and a DNA polymerase with proofreading activity for high yield and fidelity. It is optimized for PCR of DNA fragments up to 5 kb.
Use 2.6 U for a standard 50 μl PCR.

Volume activity: 3.5 U/μl

  • Use one enzyme for all applications.
Enjoy high yield, fidelity, and flexibility.
  • Detect PCR products
previously undetectable and avoid false negatives.
  • Achieve successful results
from small quantities of template DNA.

포장

1 kit containing 4 components

품질

Each lot of Expand High Fidelity is function-tested in PCR using human genomic DNA and specific primers for collagen (1 kb amplified product) and the tPA gene (4.8 kb amplified product).

단위 정의

Volume Activity: 3.5 U/μl

기타 정보

For life science research only. Not for use in diagnostic procedures.

법적 정보

Use of this product is covered by US patent claims and corresponding patent claims outside the US. The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchaser′s own internal research. No right under any other patent claim, no right to perform any patented method, and no right to perform commercial services of any kind, including without limitation reporting the results of purchaser′s activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel. This product is for research use only. Diagnostic uses under Roche patent claims require a separate license from Roche. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.</ br>NOTICE TO PURCHASER: LIMITED LICENSE<br />Use of this product is covered by US Patent No. 6,127,155 and corresponding patent claims outside the US.  The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchaser′s own internal research.  No right under any other patent claim and no right to perform commercial services of any kind, including without limitation reporting the results of purchaser′s activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel.  This product is for research use only. Human and veterinary diagnostic uses under Roche patent claims require a separate license from Roche.  All uses other than internal research and human and veterinary diagnostic uses under Roche patent claims require a separate license from Thermo Fisher Scientific. Further information on purchasing licenses from Roche may be obtained by contacting the Licensing Department of Roche Molecular Systems, Inc., 4300 Hacienda Drive, Pleasanton, California 94588, USA or Roche Diagnostics GmbH, Sandhofer Strasse 116, 68305 Mannheim, Germany.  Further information on purchasing licenses from Thermo Fisher Scientific may be obtained by contacting the Licensing Department of  Thermo Fisher Scientific, 5791 Van Allen Way, Carlsbad, California 92008, USA.
Expand is a trademark of Roche

키트 구성품 전용

제품 번호
설명

  • Expand High Fidelity Enzyme mix

  • Expand High Fidelity Buffer, with 15 mM MgCl2 10x concentrated

  • Expand High Fidelity Buffer, without MgCl2 10x concentrated

  • MgCl2 Stock Solution 25 mM

유해 및 위험 성명서

예방조치 성명서

Hazard Classifications

Aquatic Chronic 3

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 2

Flash Point (°F)

does not flash

Flash Point (°C)

does not flash


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Christopher L Corless et al.
The Journal of molecular diagnostics : JMD, 8(5), 604-612 (2006-10-27)
Oncogenic mutations of the receptor tyrosine kinase KIT contribute to the pathogenesis of gastrointestinal stromal tumors, systemic mastocytosis (SM), and some cases of acute myelogenous leukemia (AML). The D816V substitution in the activation loop of KIT results in relative resistance
Kristín Rós Kjartansdóttir et al.
PloS one, 10(12), e0144029-e0144029 (2015-12-03)
Human embryonic stem cell differentiation towards various cell types belonging to ecto-, endo- and mesodermal cell lineages has been demonstrated, with high efficiency rates using standardized differentiation protocols. However, germ cell differentiation from human embryonic stem cells has been very

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.