추천 제품
Quality Level
종 반응성
human
제조업체/상표
Milliplex®
assay range
accuracy: 87%
(Resistin)
accuracy: 89%
(Adiponectin)
sensitivity: 10 pg/mL
(MinDC+2SD; Adipsin)
sensitivity: 21 pg/mL
(MinDC+2SD; Adiponectin)
sensitivity: 3.5 pg/mL
(MinDC+2SD; Lipocalin-2/NGAL)
sensitivity: 4.4 pg/mL
(MinDC+2SD; Resistin)
sensitivity: 5.8 pg/mL
(MinDC+2SD; PAI-1)
standard curve range: 13-200,000 pg/mL
(Adipsin)
standard curve range: 26-400,000 pg/mL
(Adiponectin)
standard curve range: 3.2-50,000 pg/mL
(Lipocalin-2/NGAL)
standard curve range: 6.4-100,000 pg/mL
(Resistin)
standard curve range: 9.6-150,000 pg/mL
(PAI-1 (total))
inter-assay cv: <10%
intra-assay cv: <10%
(Adipsin)
inter-assay cv: <10%
intra-assay cv: <15%
(Adiponectin)
inter-assay cv: <10%
intra-assay cv: <15%
(Lipocalin-2/NGAL)
inter-assay cv: <10%
intra-assay cv: <20%
(PAI-1 (total))
inter-assay cv: <10%
intra-assay cv: <20%
(Resistin)
기술
multiplexing: suitable
검출 방법
fluorometric (Luminex xMAP)
배송 상태
wet ice
일반 설명
The MILLIPLEX® Human Adipokine Panel 1 is a 5-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum or plasma samples: Adiponectin, Adipsin, Lipocalin-2/NGAL, Total PAI-1, and Resistin. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
애플리케이션
- Analytes: Adiponectin Adipsin Lipocalin-2/NGAL PAI-1 (Total) Resistin
- Recommended Sample Type: Human serum and plasma
- Recommended Sample Dilution: 25 μL per well of 1:400 diluted serum or plasma
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Endocrine
특징 및 장점
기타 정보
법적 정보
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
관련 콘텐츠
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..