Key Documents

1.59014

Supelco

Acetonitrile solution

suitable for LC/MS, LiChrosolv®, contains 0.1% (v/v) trifluoroacetic acid

동의어(들):

Acetonitrile solution, ACN, ACN + TFA, Cyanomethane, Ethyl nitrile, Methyl cyanide

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
CH3CN
CAS Number:
Molecular Weight:
41.05
Beilstein:
4124158
MDL number:
UNSPSC 코드:
41116004
NACRES:
NA.03

product name

Acetonitrile with 0.1% (v:v) trifluoroacetic acid, hypergrade for LC-MS LiChrosolv®

vapor pressure

97 hPa ( 20 °C)

Quality Level

제품 라인

LiChrosolv®

형태

liquid

농도

0.095-0.105 % (v/v)

기술

LC/MS: suitable

불순물

≤0.025 ppm K (Potassium)
≤0.05 ppm Al (Aluminium)
≤0.05 ppm Ca (Calcium)
≤0.05 ppm Fe (Iron)
≤0.05 ppm Mg (Magnesium)
≤0.25 ppm Na (Sodium)

색상

APHA: ≤10

전이 온도

flash point 2 °C

density

0.782 g/mL at 25 °C

형식

mixture

저장 온도

2-30°C

SMILES string

CC#N

InChI

1S/C2H3N/c1-2-3/h1H3

InChI key

WEVYAHXRMPXWCK-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션


  • Retention time prediction for post-translationally modified peptides: Ser, Thr, Tyr-phosphorylation.: This study presents a methodology for predicting retention times of phosphorylated peptides using high-performance liquid chromatography (HPLC) (Battellino et al., 2024).

  • Development and validation of a UPLC-PDA method for quantifying ceftazidime in dried blood spots.: This paper outlines a validated ultra-performance liquid chromatography photodiode array (UPLC-PDA) method for the quantification of ceftazidime, demonstrating its application and accuracy in analyzing dried blood samples (Lv et al., 2024).

  • A facile fabric phase sorptive extraction method for monitoring chloramphenicol residues in milk samples.: Describes a new method using fabric phase sorptive extraction for the efficient monitoring of chloramphenicol in milk, highlighting its simplicity and effectiveness (Ben Ayed et al., 2024).

  • Study of sample preparation influence on bacterial lipids profile in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.: This research investigates how different sample preparation methods affect the lipid profiles of bacteria analyzed by MALDI-TOF MS, providing insights into optimizing protocols for better accuracy (Arendowski et al., 2024).

  • Simple and robust LC-MS/MS method for quantification of colistin methanesulfonate and colistin in human plasma for therapeutic drug monitoring.: This article details a robust and straightforward liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of colistin methanesulfonate and colistin in human plasma, useful in clinical settings (Kim et al., 2023).

제조 메모

Product filtered through a 0.2 μm filter

분석 메모

Acid content: 0.095 - 0.105 % (v/v)
Identity: passes test
Color: ≤ 10 Hazen
Al (Aluminium): ≤ 0.05 ppm
Ca (Calcium): ≤ 0.05 ppm
Fe (Iron): ≤ 0.05 ppm
K (Potassium): ≤ 0.025 ppm
Mg (Magnesium): ≤ 0.05 ppm
Na (Sodium): ≤ 0.25 ppm
Gradient grade (at 210 nm): ≤ 1.0 mAU
Gradient grade (at 254 nm): ≤ 0.5 mAU
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 2 ppb
Filtered by 0.2 µm filter.

기타 정보

Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

법적 정보

LICHROSOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

관련 제품

제품 번호
설명
가격

픽토그램

FlameExclamation mark

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

35.6 °F - (Acetonitrile)

Flash Point (°C)

2 °C - (Acetonitrile)


시험 성적서(COA)