1.06007
Methanol
≥99.9% (GC), gradient grade, suitable for HPLC, LiChrosolv®, reag. Ph. Eur.
동의어(들):
Methyl alcohol
About This Item
410 mmHg ( 50 °C)
97.68 mmHg ( 20 °C)
추천 제품
제품명
Methanol, gradient grade for liquid chromatography LiChrosolv® Reag. Ph Eur
Grade
gradient grade
Quality Level
Agency
reag. Ph. Eur.
vapor density
1.11 (vs air)
vapor pressure
128 hPa ( 20 °C)
410 mmHg ( 50 °C)
97.68 mmHg ( 20 °C)
제품 라인
LiChrosolv®
grade
gradient grade
분석
≥99.9% (GC)
양식
liquid
autoignition temp.
725 °F
효능
5628 mg/kg LD50, oral (Rat)
17100 mg/kg LD50, skin (Rabbit)
expl. lim.
36 %
기술
HPLC: suitable
불순물
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.02% Water
증발 잔류물
≤2.0 mg/L
색상
APHA: ≤10
투과
210 nm, ≥20%
220 nm, ≥60%
230 nm, ≥75%
235 nm, ≥83%
250 nm, ≥95%
260 nm, ≥98%
refractive index
n20/D 1.329 (lit.)
동점도
0.54-0.59 cSt(20 °C)
bp
64.7 °C (lit.)
mp
−98 °C (lit.)
전이 온도
flash point 9.7 °C
density
0.791 g/mL at 25 °C (lit.)
UV 흡수
λ: 225 nm Amax: ≤0.170
형식
neat
저장 온도
2-30°C
SMILES string
CO
InChI
1S/CH4O/c1-2/h2H,1H3
InChI key
OKKJLVBELUTLKV-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
애플리케이션
- In the mobile phase to separate mercury species on a Zorbax C18 reverse phase column.
- To wash the cartridges and as an eluent to extract the analytes during the solid-phase extraction (SPE) process.
제조 메모
분석 메모
Identity (IR): conforms
Evaporation residue: ≤ 2.0 mg/l
Water: ≤ 0.02 %
Color: ≤ 10 Hazen
Density (d 20 °C/20 °C): 0.791 - 0.793
Boiling point: 64 - 65 °C
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Gradient grade (at 235 nm): ≤ 2.0 mAU
Gradient grade (at 254 nm): ≤ 1.0 mAU
Fluorescence (as quinine at 254 nm): ≤ 1.0 ppb
Fluorescence (as quinine at 365 nm): ≤ 0.5 ppb
Transmission (at 210 nm): ≥ 20 %
Transmission (at 220 nm): ≥ 60 %
Transmission (at 230 nm): ≥ 75 %
Transmission (at 235 nm): ≥ 83 %
Transmission (at 250 nm): ≥ 95 %
Transmission (from 260 nm): ≥ 98 %
Absorbance (at 225 nm): ≤ 0.170
Filtered by 0.2 µm filter.
Suitable for UPLC / UHPLC /Ultra HPLC - instruments.
Conforms to Methanol R1 and R2 according to Reag. Ph Eur;
conforms to the requirements of ACS for liquid chromatography suitability.
기타 정보
법적 정보
관련 제품
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
표적 기관
Eyes,Central nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
49.5 °F - closed cup
Flash Point (°C)
9.7 °C - closed cup
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
문서
Apixaban is sold under the tradename Eliquis and at present no pharmacopeial monographs are available for Axpixaban using either an assay and/or organic impurity profiling method. A newly developed and validated HPLC-UV method using a column with C18 solid core particles is demonstrated.
TLC plates, with silica gel, gypsum as binder, International Pharmacopoeia compliant, for identification of Atenolol and Chlorthalidone in tablets
TLC plates, with silica gel, gypsum as binder, International Pharmacopoeia compliant, for identification of Atenolol and Chlorthalidone in tablets
In this study, LC-ESI-MS/MS under reversed phase conditions using a Superspher RP-18 column is applied to analyze dyestuffs of a reddish historic textile from South America.
프로토콜
Sildenafil Citrate Method (HPLC) following USP Monograph on Ascentis Express C18 with UV detection
Aripiprazole is an atypical antipsychotic and a partial dopamine agonist. It is primarily used in the treatment of schizophrenia, bipolar disorder, major depressive disorder, tic disorders, and irritability associated with autism. Aripiprazole was first approved by the U.S. Food and DrugAdministration in November 2002 for schizophrenia and by the European Medicines Agency in June 2004 for acute manic and mixed episodes associated with bipolar disorder.
Powdered black pepper was chosen as example for dietary supplements, being a source for pierine. It is tested according to the current United States Pharmacopeia (USP) guidelines using HPTLC and HPLC.
This application illustrate how Rutin can be determined in skin cream samples using a monolithic Chromolith® HighResolution RP-18 endcapped column with UV detection.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.