추천 제품
Grade
certified reference material
Quality Level
양식
liquid
특징
SNAP-N-SPIKE®, SNAP-N-SHOOT®
포장
ampule of 1 mL
제조업체/상표
Cerilliant®
농도
1.0 mg/mL in methanol (as free base)
기술
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
응용 분야
clinical testing
형식
single component solution
저장 온도
−20°C
SMILES string
Cl.CCCCc1oc2ccccc2c1C(=O)c3cc(I)c(OCCN(CC)CC)c(I)c3
InChI
1S/C25H29I2NO3.ClH/c1-4-7-11-22-23(18-10-8-9-12-21(18)31-22)24(29)17-15-19(26)25(20(27)16-17)30-14-13-28(5-2)6-3;/h8-10,12,15-16H,4-7,11,13-14H2,1-3H3;1H
InChI key
ITPDYQOUSLNIHG-UHFFFAOYSA-N
유전자 정보
human ... KCNH2(3757)
일반 설명
애플리케이션
- Amiodarone Hydrochloride in Atrial Fibrillation: For treating paroxysmal atrial fibrillation, utilizing Amiodarone HCl as a control for arrhythmic events during treatment, highlighting its pivotal role in managing cardiac arrhythmias (Metzner et al., 2024).
- Targeted Drug Delivery Research: Amiodarone is used in targeted therapy that enhances the drug′s effectiveness and reduces systemic side effects, particularly in treating cardiac conditions (Zahid et al., 2023).
법적 정보
관련 제품
애플리케이션
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
표적 기관
Eyes,Central nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
49.5 °F - closed cup
Flash Point (°C)
9.7 °C - closed cup
가장 최신 버전 중 하나를 선택하세요:
문서
For efficient therapeutic drug monitoring, it is important for clinicians to have access to fast and robust analytical methods for accurate assessment of drug efficacy. Industrial trends toward highly specific LC/MS applications over traditional immunoassay have resulted in the need for high-speed chromatographic assays along with simplified sample preparation methods.
The benefit of HILIC over traditional reversed-phase chromatography is two-fold for both sample introduction and analyte detection. First, the high acetonitrile concentration of HILIC mobile phases allows for direct analysis of precipitated plasma samples without the need for additional sample solvent exchange. Second, the high acetonitrile content provides increased analyte response in positive ESI MS detection.
프로토콜
LC/MS/MS Analysis of Interacting Cardiac Drugs Digoxin, Quinidine, Amiodarone and Verapamil on Titan™ C18
Chromatograms
application for HPLCapplication for HPLCapplication for HPLC자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..