콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

W504904

Sigma-Aldrich

Butyrophenone

≥99%

동의어(들):

1-Benzoylpropane, 1-Phenyl-1-butanone, NSC 8463, Phenyl propyl ketone

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
C6H5COCH2CH2CH3
CAS Number:
Molecular Weight:
148.20
Beilstein:
508305
EC Number:
MDL number:
UNSPSC 코드:
12164502
PubChem Substance ID:
플래비스(Flavis) 번호:
7.193
NACRES:
NA.21

생물학적 소스

synthetic

분석

≥99%

refractive index

n20/D 1.520 (lit.)

bp

228-230 °C (lit.)

mp

11-13 °C (lit.)

density

1.021 g/mL at 25 °C (lit.)

응용 분야

flavors and fragrances

문건

see Safety & Documentation for available documents

식품 알레르기항원

no known allergens

감각 수용성의

camphoraceous

SMILES string

CCCC(=O)c1ccccc1

InChI

1S/C10H12O/c1-2-6-10(11)9-7-4-3-5-8-9/h3-5,7-8H,2,6H2,1H3

InChI key

FFSAXUULYPJSKH-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

Storage Class Code

10 - Combustible liquids

WGK

WGK 3

Flash Point (°F)

190.4 °F

Flash Point (°C)

88 °C

개인 보호 장비

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Fabrice Gritti et al.
Journal of chromatography. A, 1410, 118-128 (2015-08-10)
An original method is proposed for the accurate and reproducible measurement of the time-based dispersion properties of short L< 50cm and narrow rc< 50μm tubes at mobile phase flow rates typically used in very high-pressure liquid chromatography (vHPLC). Such tubes
Fabrice Gritti et al.
Journal of chromatography. A, 1420, 54-65 (2015-10-17)
The impact of the column hardware volume (≃ 1.7 μL) on the optimum reduced plate heights of a series of short 2.1 mm × 50 mm columns (hold-up volume ≃ 80-90 μL) packed with 1.8 μm HSS-T3, 1.7 μm BEH-C18
Ruben De Pauw et al.
Journal of chromatography. A, 1420, 129-134 (2015-10-20)
A new system is proposed for applying fast temperature gradients in liquid chromatography. It consists of a 0.7 mm × 150 mm fused-silica column coated with a 50 μm Nickel-layer, which is connecting with a power source and a temperature
Zsolt Székelyhidi et al.
Bioorganic & medicinal chemistry letters, 15(13), 3241-3246 (2005-06-01)
SR protein-specific kinase-1 (SRPK-1) has been identified as a validated target for hepatitis B virus (HBV). A series of novel tricyclic quinoxaline derivatives was designed and synthesised as potential kinase inhibitory antiviral agents and was found to be active and
Nikola Vaňková et al.
Journal of chromatography. A, 1409, 152-158 (2015-07-29)
The effect of gradient steepness on the kinetic performance limits and peak compression effects has been assessed in gradient mode for the separation of phenol derivatives using columns packed with 2.6μm core-shell particles. The effect of mobile-phase velocity on peak

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.