추천 제품
분석
≥99%
양식
liquid
refractive index
n20/D 1.520 (lit.)
bp
228-230 °C (lit.)
mp
11-13 °C (lit.)
density
1.021 g/mL at 25 °C (lit.)
작용기
ketone
phenyl
SMILES string
CCCC(=O)c1ccccc1
InChI
1S/C10H12O/c1-2-6-10(11)9-7-4-3-5-8-9/h3-5,7-8H,2,6H2,1H3
InChI key
FFSAXUULYPJSKH-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Butyrophenone has been used to study the relationship between the electrolyte counter-ion concentration and the critical micelle concentration for several surfactants. It has been used to generate PhCO+ ions by 70 eV electron ionization.
생화학적/생리학적 작용
Butyrophenones constitutes neuroleptic drugs and interacts with the opiate receptor by inhibiting the stereospecific binding of 3H-naloxone.
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
Flash Point (°F)
190.4 °F
Flash Point (°C)
88 °C
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Hao Chen et al.
Journal of the American Society for Mass Spectrometry, 14(3), 182-188 (2003-03-22)
Phosphonium ions CH(3)P(O)OCH(3)(+) (93 Th) and CH(3)OP(O)OCH(3)(+) (109 Th) react with 1,4-dioxane to form unique cyclic ketalization products, 1,3,2-dioxaphospholanium ions. By contrast, a variety of other types of ions having multiple bonds, including the acylium ions CH(3)CO(+) (43 Th), CH(3)OCO(+)
Critical micelle concentration of surfactants in aqueous buffered and unbuffered systems.
Fuguet E, et al.
Analytica Chimica Acta, 548(1), 95-100 (2005)
I Creese et al.
European journal of pharmacology, 36(1), 231-235 (1976-03-01)
Interaction of neuroleptic drugs with the opiate receptors was investigated by inhibition of the stereospecific binding of 3H-naloxone. Benperidol and pimozide, with IC50's of 0.3-0.5 muM, were more potent than the classical opiates meperidine and propoxyphene. A systematic structure-activity relationship
Fabrice Gritti et al.
Journal of chromatography. A, 1410, 118-128 (2015-08-10)
An original method is proposed for the accurate and reproducible measurement of the time-based dispersion properties of short L< 50cm and narrow rc< 50μm tubes at mobile phase flow rates typically used in very high-pressure liquid chromatography (vHPLC). Such tubes
Fabrice Gritti et al.
Journal of chromatography. A, 1420, 54-65 (2015-10-17)
The impact of the column hardware volume (≃ 1.7 μL) on the optimum reduced plate heights of a series of short 2.1 mm × 50 mm columns (hold-up volume ≃ 80-90 μL) packed with 1.8 μm HSS-T3, 1.7 μm BEH-C18
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.