추천 제품
Grade
for analytical purposes
분석
99.999% trace metals basis
양식
solid
불순물
≤15.0 ppm Trace Metal Analysis
mp
626 °C (lit.)
density
4.51 g/mL at 25 °C (lit.)
SMILES string
[I-].[Cs+]
InChI
1S/Cs.HI/h;1H/q+1;/p-1
InChI key
XQPRBTXUXXVTKB-UHFFFAOYSA-M
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Cesium iodide can be used as precursor to synthesize lead-free perovskite material, Cs2NaBiI6 (CNBI). The CNBI is highly stable and finds application in the field of solar cells, LEDs, and lasers.
It can be used to prepare brightest red emitting Cs2HfI6 scintillator which is applicable in high resolution gamma spectroscopy.
It can also be used tosynthesize Cesium based nanocrystals for the detection of ionizingradiations.
It can be used to prepare brightest red emitting Cs2HfI6 scintillator which is applicable in high resolution gamma spectroscopy.
It can also be used tosynthesize Cesium based nanocrystals for the detection of ionizingradiations.
특징 및 장점
- High quantum efficiency
- High stability to ambient air and gas environment
Frequently used in devices such as phosphor screens for medical imaging, scintillators, calorimeters and a variety of particle detectors.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Aquatic Acute 1 - Repr. 2
Storage Class Code
13 - Non Combustible Solids
WGK
WGK 2
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
이미 열람한 고객
Nobuhiro Yasui et al.
Advanced materials (Deerfield Beach, Fla.), 24(40), 5464-5469 (2012-08-14)
Alkali halide systems that function as phase-separated scintillators (PSSs) with light-guiding properties are sucessfully created. Furthermore, it is the matrix phases of the PSSs which display the light-guiding properties. CsI-NaCl:Tl is a practical material pair because of its high pixel
Tetsuro Matsumoto et al.
Radiation protection dosimetry, 146(1-3), 92-95 (2011-04-29)
A small-sized thermal neutron detector based on a (6)Li-glass scintillator and a plastic optical fibre has been developed for precise measurement of the spatial distribution of thermal neutron fluence rate. This detector was tested in experiments performed using thermal neutrons.
K J Tielrooij et al.
The journal of physical chemistry. B, 115(43), 12638-12647 (2011-09-10)
We study the reorientation dynamics of water molecules around ions using terahertz dielectric relaxation spectroscopy and polarization-resolved femtosecond infrared pump-probe spectroscopy. The results are discussed in relation to the ion-specific Hofmeister series and the concomitant "structure-making" and "structure-breaking" effects of
Marco Bertolini et al.
Medical physics, 39(5), 2617-2627 (2012-05-09)
The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer
Melanie Freed et al.
Medical physics, 37(6), 2593-2605 (2010-07-17)
Accurate models of detector blur are crucial for performing meaningful optimizations of three-dimensional (3D) x-ray breast imaging systems as well as for developing reconstruction algorithms that faithfully reproduce the imaged object anatomy. So far, x-ray detector blur has either been
문서
Colloidal quantum dots (CQDs) are semiconducting crystals of only a few nanometers (ca. 2–12 nm) coated with ligand/surfactant molecules to help prevent agglomeration.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.