추천 제품
Quality Level
분석
98%
양식
liquid
refractive index
n20/D 1.443 (lit.)
bp
92 °C (lit.)
mp
−34 °C (lit.)
density
1.158 g/mL at 25 °C (lit.)
작용기
fluoro
SMILES string
Fc1ccccc1F
InChI
1S/C6H4F2/c7-5-3-1-2-4-6(5)8/h1-4H
InChI key
GOYDNIKZWGIXJT-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
1,2-Difluorobenzene undergoes defluorination under very mild conditions by H2 in the presence of NaOAc over rhodium pyridylphosphine and bipyridyl complexes tethered on a silica-supported palladium catalyst.
애플리케이션
1,2-Difluorobenzene(1,2-DFB) has been used to study the mechanism of dissociation of o-, m- and p-difluorobenzene ions by threshold photoelectron photoion coincidence spectroscopy. It has been used to study the room temperature adsorption of 1,2-DFB, 1,2-dichlorobenzene and 1,2-dibromobenzene on Si(100)2x1 by X-ray photoelectron spectroscopy and temperature programmed desorption. It was used as solvent in electrochemical studies on transition metal complexes.
Solvent useful for electrochemical studies on transition metal complexes.
이미 열람한 고객
Hydrodefluorination of fluorobenzene and 1, 2-difluorobenzene under mild conditions over rhodium pyridylphosphine and bipyridyl complexes tethered on a silica-supported palladium catalyst.
Yang H, et al.
Organometallics, 18(12), 2285-2287 (1999)
Competition between associative and dissociative adsorption of 1, 2-dihalogenated benzenes on Si (100) 2? 1: Formation of dihalocyclohexadiene, halophenyl and phenylene adstructures.
Zhou XJ and Leung KT.
Surface Science, 600(16), 3285-3296 (2006)
Anne-Marie Boulanger et al.
Journal of the American Society for Mass Spectrometry, 20(1), 20-24 (2008-10-18)
Threshold photoelectron photoion coincidence (TPEPICO) experiments have shown that o-, m-, and p-difluorobenzene ions dissociate via a common, ring-opened intermediate and not via ionized p-difluorobenzene. Rice-Ramsperger-Kassel-Marcus (RRKM) modeling of the experimental breakdown curves yields activation energies for the initial isomerization
Inorganic Chemistry, 28, 3923-3923 (1989)
Adrian Romero-Flores et al.
Chemosphere, 186, 151-159 (2017-08-05)
Electronic noses have been widely used in the food industry to monitor process performance and quality control, but use in wastewater and biosolids treatment has not been fully explored. Therefore, we examined the feasibility of an electronic nose to discriminate
Global Trade Item Number
SKU | GTIN |
---|---|
126152-10G | 4061838723871 |
126152-50G | 4061838723888 |
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.