コンテンツへスキップ
Merck
  • Measurement of a Comprehensive Sex Steroid Profile in Rodent Serum by High-Sensitive Gas Chromatography-Tandem Mass Spectrometry.

Measurement of a Comprehensive Sex Steroid Profile in Rodent Serum by High-Sensitive Gas Chromatography-Tandem Mass Spectrometry.

Endocrinology (2015-04-10)
Maria E Nilsson, Liesbeth Vandenput, Åsa Tivesten, Anna-Karin Norlén, Marie K Lagerquist, Sara H Windahl, Anna E Börjesson, Helen H Farman, Matti Poutanen, Anna Benrick, Manuel Maliqueo, Elisabet Stener-Victorin, Henrik Ryberg, Claes Ohlsson
要旨

Accurate measurement of sex steroid concentrations in rodent serum is essential to evaluate mouse and rat models for sex steroid-related disorders. The aim of the present study was to develop a sensitive and specific gas chromatography-tandem mass spectrometry (GC-MS/MS) method to assess a comprehensive sex steroid profile in rodent serum. A major effort was invested in reaching an exceptionally high sensitivity for measuring serum estradiol concentrations. We established a GC-MS/MS assay with a lower limit of detection for estradiol, estrone, T, DHT, progesterone, androstenedione, and dehydroepiandrosterone of 0.3, 0.5, 4.0, 1.6, 8, 4.0, and 50 pg/mL, respectively, whereas the corresponding values for the lower limit of quantification were 0.5, 0.5, 8, 2.5, 74, 12, and 400 pg/mL, respectively. Calibration curves were linear, intra- and interassay coefficients of variation were low, and accuracy was excellent for all analytes. The established assay was used to accurately measure a comprehensive sex steroid profile in female rats and mice according to estrous cycle phase. In addition, we characterized the impact of age, sex, gonadectomy, and estradiol treatment on serum concentrations of these sex hormones in mice. In conclusion, we have established a highly sensitive and specific GC-MS/MS method to assess a comprehensive sex steroid profile in rodent serum in a single run. This GC-MS/MS assay has, to the best of our knowledge, the best detectability reported for estradiol. Our method therefore represents an ideal tool to characterize sex steroid metabolism in a variety of sex steroid-related rodent models and in human samples with low estradiol levels.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
プロゲステロン, powder, BioReagent, suitable for cell culture
Sigma-Aldrich
エストラジオール, meets USP testing specifications
Sigma-Aldrich
エストロン, ≥99%
Sigma-Aldrich
トルエン, anhydrous, 99.8%
Sigma-Aldrich
2,2,4-トリメチルペンタン, JIS special grade
Sigma-Aldrich
trans-デヒドロアンドロステロン, ≥99%
Sigma-Aldrich
ピリジン, ≥99%
Sigma-Aldrich
ピリジン, anhydrous, 99.8%
Sigma-Aldrich
プロゲステロン, meets USP testing specifications
Sigma-Aldrich
トルエン, SAJ first grade, ≥99.0%
Sigma-Aldrich
プロゲステロン, γ-irradiated, BioXtra, suitable for cell culture
Sigma-Aldrich
ヘプタン, anhydrous, 99%
Sigma-Aldrich
2,2,4-トリメチルペンタン, anhydrous, 99.8%
Sigma-Aldrich
トルエン, JIS special grade, ≥99.5%
Sigma-Aldrich
ペンタン, anhydrous, ≥99%
Sigma-Aldrich
ピリジン, JIS special grade, ≥99.5%
Sigma-Aldrich
ペンタン, SAJ special grade, ≥99.0%
Sigma-Aldrich
1-クロロブタン, anhydrous, 99.5%
Sigma-Aldrich
プロゲステロン-2,3,4-13C3, 99 atom % 13C, 98% (CP)
Sigma-Aldrich
トルエン, JIS 300, for residue analysis, ≥99.8%
Sigma-Aldrich
ヘプタン, JIS special grade, ≥99.0%
Sigma-Aldrich
ヘプタン, SAJ first grade, ≥98.0%
Sigma-Aldrich
2,2,4-トリメチルペンタン, SAJ first grade, ≥98.0%
Sigma-Aldrich
ピリジン, suitable for hydroxyl value determination, ≥99.5%
Sigma-Aldrich
トルエン, suitable for HPLC, ≥99.9%
Sigma-Aldrich
2,2,4-トリメチルペンタン, ≥99.5%, suitable for absorption spectrum analysis
Sigma-Aldrich
ペンタン, SAJ first grade, ≥96.0%
Sigma-Aldrich
トルエン, JIS 1000, for residue analysis, ≥99.8%