コンテンツへスキップ
Merck
  • Critical evaluation of the 2D-CSIA scheme for distinguishing fuel oxygenate degradation reaction mechanisms.

Critical evaluation of the 2D-CSIA scheme for distinguishing fuel oxygenate degradation reaction mechanisms.

Environmental science & technology (2012-03-30)
Mònica Rosell, Rafael Gonzalez-Olmos, Thore Rohwerder, Klara Rusevova, Anett Georgi, Frank-Dieter Kopinke, Hans H Richnow
要旨

Although the uniform initial hydroxylation of methyl tert-butyl ether (MTBE) and other oxygenates during aerobic biodegradation has already been proven by molecular tools, variations in carbon and hydrogen enrichment factors (ε(C) and ε(H)) have still been associated with different reaction mechanisms (McKelvie et al. Environ. Sci. Technol. 2009, 43, 2793-2799). Here, we present new laboratory-derived ε(C) and ε(H) data on the initial degradation mechanisms of MTBE, ethyl tert-butyl ether (ETBE), and tert-amyl methyl ether (TAME) by chemical oxidation (permanganate, Fenton reagents), acid hydrolysis, and aerobic bacteria cultures (species of Aquincola, Methylibium, Gordonia, Mycobacterium, Pseudomonas, and Rhodococcus). Plotting of Δδ(2)H/ Δδ(13)C data from chemical oxidation and hydrolysis of ethers resulted in slopes (Λ values) of 22 ± 4 and between 6 and 12, respectively. With A. tertiaricarbonis L108, R. zopfii IFP 2005, and Gordonia sp. IFP 2009, ε(C) was low (<|-1|‰) and ε(H) was insignificant. Fractionation obtained with P. putida GPo1 was similar to acid hydrolysis and M. austroafricanum JOB5 and R. ruber DSM 7511 displayed Λ values previously only ascribed to anaerobic attack. The fractionation patterns rather correlate with the employment of different P450, AlkB, and other monooxygenases, likely catalyzing ether hydroxylation via different transition states. Our data questions the value of 2D-CSIA for a simple distinguishing of oxygenate biotransformation mechanisms, therefore caution and complementary tools are needed for proper interpretation of groundwater plumes at field sites.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
tert-ブチルメチルエーテル, suitable for HPLC, ≥99.8%
Sigma-Aldrich
tert-ブチルメチルエーテル, ACS reagent, ≥99.0%
Sigma-Aldrich
tert-ブチルメチルエーテル, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
tert-ブチルメチルエーテル, reagent grade, ≥98%
Sigma-Aldrich
tert-ブチルメチルエーテル, puriss. p.a., ≥99.5% (GC)
Sigma-Aldrich
tert-ブチルエチルエーテル, 99%
Sigma-Aldrich
tert-ブチルメチルエーテル, anhydrous, 99.8%
Sigma-Aldrich
tert-ブチルメチルエーテル, reagent grade, 98%
Supelco
tert-ブチルエチルエーテル, analytical standard
Supelco
tert-ブチルメチルエーテル, analytical standard
Sigma-Aldrich
tert-ブチルメチルエーテル, SAJ special grade, ≥99.0%
Sigma-Aldrich
tert-ブチルエチルエーテル, purum, ≥97.0% (GC)
Supelco
tert-ブチルメチルエーテル, suitable for HPLC, ≥99.8% (GC)
Sigma-Aldrich
tert-ブチルメチルエーテル, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%