おすすめの製品
認証
meets requirements for USP G2
包装
bottle of 10 g
パラメーター
temp. range at 50-300 °C
テクニック
gas chromatography (GC): suitable
マトリックス活性基
SE-30 phase
溶解性
chloroform: soluble
カラムタイプ
packed GC
詳細
GC methods are divided into two classes depending on the nature of stationary phases; gas-solid chromatography (GSC) and gas-liquid chromatography (GLC). GSC has solid adsorptive material and solute particles are removed from mobile phase by electrostatic forces. GLC has a thin layer of liquid coated or bonded on the surface of an inert particle or on the walls of the column where solute particles are retained in the liquid phase based on their partition coefficients. The primary necessity of a stationary phase is to provide sample separation sustaining phase integrity over a reasonable period of time. It should be stable for the chemical and thermal changes. Selectivity, peak symmetry, analysis time, degree of separation, peak tailing are a few parameters that should be considered before choosing a stationary phase. SE-30 is a dimethyl silicone elastomer. It is widely suitable as liquid phase got GLC.
GCの固定相として使用するために、純度を高く、分子量範囲を狭く、痕跡レベルの触媒や不純物を含まないように特に合成しました。
アプリケーション
SE-30 was used as stationary phase for the analysis of the thiohydantoins using GC. It may also be used as liquid phase in identification of the single polychlorinated biphenyls (PCB) components by comparing their retention indices, using high-resolution thin-film glass capillary gas chromatography coupled with electron-capture detector.
保管分類コード
10 - Combustible liquids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
個人用保護具 (PPE)
Eyeshields, Gloves
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
21099-U:
最新バージョンのいずれかを選択してください:
Analysis of polychlorinated biphenyls (PCB) by glass capillary gas chromatography.
Fresenius' Zeitschrift fur Analytische Chemie, 302, 20-31 (1980)
Journal of chromatography, 113(1), 69-95 (1975-03-12)
The dimethyl silicone elastomer SE-30 has been chosen as the preferred liquid phase for the gas-liquid chromatographic analysis of drugs, and retention index data have been compiled for 480 drugs and commonly occurring chemicals such as plasticisers. The inter-laboratory variation
Analysis of amino acid phenylthiohydantoins by gas chromatography.
The Journal of biological chemistry, 244(20), 5597-5607 (1969-10-25)
Methods of Air Sampling and Analysis, 98-98 (1988)
Remington: The Science and Practice of Pharmacy, 605-605 (2006)
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)