製品名
BioTracker™ Blue Live Cell Cycle Assay Solution,
由来生物
human
品質水準
包装
vial of 50 tests
メーカー/製品名
Millipore
テクニック
cell culture | stem cell: suitable
flow cytometry: suitable
輸送温度
dry ice
保管温度
−20°C
詳細
Propidium iodide (PI) is often used for cell cycle analysis by flow cytometry. Compared to this analysis method, the BioTracker™ Far Red Live Cell Cycle Assay Solution does not require cell fixation or permeabilization, and is permeable in live cells. Use 5 uL of probe solution in 500 uL for each sample. Vial contains enough for 50 tests.IMPORTANT APPLICATION NOTES:*Wash cells thoroughly to remove trypsin. Residual trypsin can confound analysis of flow cytometry populations.*Adjust gates after cells are stained with probe SPECTRAL PROPERTIESExcitation: 405 - 407 nmEmission: 450/50 BPUse violet laser for excitation.
特徴および利点
Blue fluorescence probe for analysis of the cell cycle by flow cytometry.
ターゲットの説明
The control mechanism of the cell cycle is closely linked to cell proliferation. The cell cycle includes cell division, in which one cell produces two daughter cells. The cell cycle can be assessed by detecting cells stained for DNA using flow cytometry, followed by analysis of the proportion of stained nuclei in cell cycle phase. The cell cycle is classified into two major phases: interphase and the mitotic (M) phase. Interphase is composed of G1 phase (preparation for DNA synthesis which occurs prior to cell division), S phase (DNA synthesis and replication), and G2 phase (chromosome duplication). M phase involves mitosis and cytokinesis. Cell cycle progression is regulated by cyclins and cyclin-dependent kinases. To determine the action of drugs such as anticancer therapeutics, it is essential to analyze the mechanism of cell-cycle checkpoint.
保管および安定性
Store BioTracker™ Blue Live Cell Cycle Assay Solution at -20 °C, protected from light.
その他情報
Live cell probe for fluorescent cell cycle analysis. Unlike propidium iodide (PI), this probe is membrane permeable and highly specific for DNA, which makes it possible to analyze the cell cycle by simply adding the reagent to a cell suspension without any fixation, permeabilization, or other sample prep.
法的情報
BioTracker is a trademark of Merck KGaA, Darmstadt, Germany
免責事項
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
シグナルワード
Danger
危険有害性情報
危険有害性の分類
Aquatic Chronic 2 - Eye Dam. 1
保管分類コード
12 - Non Combustible Liquids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
PRTR
第一種指定化学物質
労働安全衛生法名称等を表示すべき危険物及び有害物
名称等を表示すべき危険物及び有害物
労働安全衛生法名称等を通知すべき危険物及び有害物
名称等を通知すべき危険物及び有害物
Jan Code
SCT281:
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。